<data xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<row _id="1"><Development Name>Anglesey House (W)</Development Name><Location>Blackrock</Location><bldg__ctrl__no_>BC 1845</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Anglesey House BC1845</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="2"><Development Name>Ardmore Park (E)</Development Name><Location>Sallynogin</Location><bldg__ctrl__no_>BC 1814</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Ardmore Park BC1814</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="3"><Development Name>Barclay Court (W)</Development Name><Location>Blackrock</Location><bldg__ctrl__no_>BC 1854</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Barclay Court BC1854</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="4"><Development Name>Carrickmines Manor (E)</Development Name><Location>Carrickmines</Location><bldg__ctrl__no_>BC 1847</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Carrickmines Manor BC1847</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>No drainage information available</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="5"><Development Name>Cherrywood Town City (E)</Development Name><Location>Cherrywood</Location><bldg__ctrl__no_>BC 1859</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Cherrywood T.C BC1859</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="6"><Development Name>Clonbur (E)</Development Name><Location>Foxrock</Location><bldg__ctrl__no_>BC 1858</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Clonbur Foxrock BC1858</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="7"><Development Name>Feldberg</Development Name><Location>Glenageary</Location><bldg__ctrl__no_>BC 1846</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Feldberg BC1846</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="8"><Development Name>Flanagan's</Development Name><Location>Mount Merrion</Location><bldg__ctrl__no_>BC 1863</bldg__ctrl__no_><Status>Major Issue</Status><Hyperlink>Flanagan's Mount Merrion BC1863</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Empty File Folder</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="9"><Development Name>Fortwilliam Cottages (E)</Development Name><Location>-</Location><bldg__ctrl__no_>BC 1828</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Fortwilliam Cottages BC1828</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="10"><Development Name>Greythorn Manor (E)</Development Name><Location>Glenageary</Location><bldg__ctrl__no_>BC 1823</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Greythorn Manor BC1823</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="11"><Development Name>Hazelbrook Sq. The Court</Development Name><Location>Rathfarnham</Location><bldg__ctrl__no_>BC 1861</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Hazelbrook Sq. The Court BC1861</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="12"><Development Name>Kilmacud House (E)</Development Name><Location>Stillorgan</Location><bldg__ctrl__no_>BC 1848</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Kilmacud House BC1848</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="13"><Development Name>Library Road (E)</Development Name><Location>Shankill</Location><bldg__ctrl__no_>BC 1830</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Library Rd. Shankill BC1830</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no surface water drainage shown on drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="14"><Development Name>Quarry Rd (E)</Development Name><Location>Rathmichael</Location><bldg__ctrl__no_>BC 1834</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Quarry Rd BC1834</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="15"><Development Name>Rosemount Cottage (W)</Development Name><Location>Dundrum</Location><bldg__ctrl__no_>BC 1853</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Rosemount Cottage BC1853</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="16"><Development Name>Stillorgan Park (E)</Development Name><Location>Stillorgan</Location><bldg__ctrl__no_>BC 1855</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Stillorgan Park BC1855</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File no drainage drawing</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="17"><Development Name>Trimbleston Phase 2 (W)</Development Name><Location>-</Location><bldg__ctrl__no_>-</bldg__ctrl__no_><Status>Major Issue</Status><Hyperlink>-</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>-</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Empty File Folder</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="18"><Development Name>Adelaide Rd (E)</Development Name><Location>Dun Laoghaire</Location><bldg__ctrl__no_>BC 1840</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Adelaide Rd BC1840</Hyperlink><Consultant Engineers>DBFL</Consultant Engineers><suds_built__y_n_>No</suds_built__y_n_><h_brake_1__y___n_>`-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>No attenuation details</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="19"><Development Name>Belmont Sector 2 (W)</Development Name><Location>Sandyford</Location><bldg__ctrl__no_>BC 1738.2</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Belmont-Sector 2 BC1738.2</Hyperlink><Consultant Engineers>DBFL</Consultant Engineers><suds_built__y_n_>No</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Apparently no attenuation present. FW and SW shown on drawing 133082 but not directly associated with Belmont Development</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="20"><Development Name>Brookside (E)</Development Name><Location>Blackrock</Location><bldg__ctrl__no_>BC 1851</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Brookside BC1851</Hyperlink><Consultant Engineers>Virtus Construction Consultants</Consultant Engineers><suds_built__y_n_>No</suds_built__y_n_><h_brake_1__y___n_>No</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>Soakaway</SUDS Type 1><SUDS Measure Description 1>Multiple Cultec Soakaways, one soakaway per house</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="21"><Development Name>Carrrickmines Green (E)</Development Name><Location>Carrickmines</Location><bldg__ctrl__no_>BC 1588</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Carrickmines Green BC1588</Hyperlink><Consultant Engineers>Waterman Moylans</Consultant Engineers><suds_built__y_n_>No</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="22"><Development Name>Clonlost House (E)</Development Name><Location>Dalkey</Location><bldg__ctrl__no_>BC 1788</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Clonlost House BC1788</Hyperlink><Consultant Engineers>ONCE Civil &amp; Structural</Consultant Engineers><suds_built__y_n_>No</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>No details</Hydrobrake Details><SUDS Type 1>Oversized Pipe</SUDS Type 1><SUDS Measure Description 1>900mm Dia Oversized pipe</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="23"><Development Name>Clon Brugh</Development Name><Location>Aikens Village</Location><bldg__ctrl__no_>BC1485A</bldg__ctrl__no_><Status>TIC Files - Incomplete</Status><Hyperlink>Clon Brugh BC1485A</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>No</suds_built__y_n_><h_brake_1__y___n_>No</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="24"><Development Name>Greygates (W)</Development Name><Location>Mount Merrion</Location><bldg__ctrl__no_>BC 1820</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Greygates BC1820</Hyperlink><Consultant Engineers>Duffy Chartered Engineers</Consultant Engineers><suds_built__y_n_>No</suds_built__y_n_><h_brake_1__y___n_>No</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>Enlarged Pipe</SUDS Type 1><SUDS Measure Description 1>600mm diameter pipe providing approximately 23m3 attenuation</SUDS Measure Description 1><SUDS Type 2>Rainwater Harvesting Tank</SUDS Type 2><SUDS Measure Description 2>8000 litre rainwater harvesting tank</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>600mm diameter pipe used as attenuation, pipe is very close to building foundations. There is a wayleave but it is extend to one side only.</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="25"><Development Name>Kenlar (W)</Development Name><Location>Sandyford</Location><bldg__ctrl__no_>BC 1815</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Kenler BC1815</Hyperlink><Consultant Engineers>Pat O'Gorman &amp; Associates</Consultant Engineers><suds_built__y_n_>No</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Rainwater Butts and Soakaways present</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="26"><Development Name>Royal Marine Hotel</Development Name><Location>Dun Laoghaire</Location><bldg__ctrl__no_>BC 1789</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Royal Marine Hotel BC 1789</Hyperlink><Consultant Engineers>Muir Assoicates Ltd</Consultant Engineers><suds_built__y_n_>No</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="27"><Development Name>Springhill House (E)</Development Name><Location>Killiney</Location><bldg__ctrl__no_>BC 1798</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Springhill House BC1798</Hyperlink><Consultant Engineers>Killiney Design Associates</Consultant Engineers><suds_built__y_n_>No</suds_built__y_n_><h_brake_1__y___n_>No</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>No Attenuation</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="28"><Development Name>214 Rochestown Ave (E) - Auburn Green</Development Name><Location>Glenageary</Location><bldg__ctrl__no_>BC 1841</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>214 Rochestown Ave. BC1841</Hyperlink><Consultant Engineers>Barrett Mahony Con. Eng</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 3.3 l/s, minimum size of hydrobrake opening to be 75mm</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Stormtech SC-740, 66m3. IL 45.782 / TOW 46.850</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files>Existing Foul and Surface Water have been diverted to proposed FW and SW systems. Onsite company director Matthew Lyster (0866676768)</Comments - Additional Files></row>
<row _id="29"><Development Name>Aiken Village,Dun Gaoithe (W)</Development Name><Location>Dun Laoghaire</Location><bldg__ctrl__no_>BC 1842</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Aiken Village,Dun Gaoithe BC1842</Hyperlink><Consultant Engineers>CS Consulting Group</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 4.1 l/s,  CL 121.60, IL 116.222</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Stormtech, 335m3</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Minimal Details on attenuation details</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="30"><Development Name>Ard na Geine (W)</Development Name><Location>Churchtown</Location><bldg__ctrl__no_>BC 1831</bldg__ctrl__no_><Status>TIC Files - Complete</Status><Hyperlink>Ard na Geine BC1831</Hyperlink><Consultant Engineers>Kavanagh Burke Con.Engs</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>Soakaway</SUDS Type 1><SUDS Measure Description 1>Soakaway Stormtech x 2, No volume shown on the drawing</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Drainage drawing found in TIC files</Comments><Comments - Additional Files>-</Comments - Additional Files></row>
<row _id="31"><Development Name>Ardilea Cresent (W)</Development Name><Location>Clonskeagh</Location><bldg__ctrl__no_>BC1776</bldg__ctrl__no_><Status>TIC Files - Complete</Status><Hyperlink>Ardilea Crescent BC1776</Hyperlink><Consultant Engineers>DBFL</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Not on dwg. Prob. S4A</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Attenuation tank to store run off for 1 in 100 year storm. TWL=51.10m AOD, IL=49.60m, GL=52.00m. Dimensions=160m2 x 1.5m Deep, Volume=240m3, Dividing Weir Level=50.80m</SUDS Measure Description 1><SUDS Type 2>Green Roof on apartment blocks</SUDS Type 2><SUDS Measure Description 2>No details</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments xsi:nil="true" /><Comments - Additional Files>Multiple issues with SW pipes, these include water infiltration, connections not sealed and joint gaps. Developer was O'Malley Construction</Comments - Additional Files></row>
<row _id="32"><Development Name>Balure (E)</Development Name><Location>Glenageary</Location><bldg__ctrl__no_>BC1774</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Balure BC1774</Hyperlink><Consultant Engineers>GNCE</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Flow restricted to 2.0l/s (S4)</Hydrobrake Details><SUDS Type 1>Stormtech</SUDS Type 1><SUDS Measure Description 1>"Designed for a 100yr event with a storage required of 115.0m3. IL 48.94m3"</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="33"><Development Name>Beech Park</Development Name><Location>Cabinteely</Location><bldg__ctrl__no_>BC 1864</bldg__ctrl__no_><Status xsi:nil="true" /><Hyperlink>Beechpark Cabinteely BC1864</Hyperlink><Consultant Engineers>Muir Associates</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Y</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 9.6l/s / Hydrobrake, Discharge Limited to 1.0l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>"Proposed Underground 95% Void Ratio Modular Storage"</SUDS Measure Description 1><SUDS Type 2>Temporary pond</SUDS Type 2><SUDS Measure Description 2>Temporary surface water treatment and attenuation, discharge limited to 9.0 l/s</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>All SUDS measures to be place under road?</Comments><Comments - Additional Files>Latest drawing is for enabling works and does not show the drainage plans for the apartment block to the East of the site.</Comments - Additional Files></row>
<row _id="34"><Development Name>Belarmine Ph.3 (W)</Development Name><Location>Stepaside</Location><bldg__ctrl__no_>BC 1849</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Belarmine Ph.3 BC1849</Hyperlink><Consultant Engineers>Waterman Moylans</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 1.6l/s Hydrobrake, Discharge Limited to 3.6l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Stormtec, Volume  241m3</SUDS Measure Description 1><SUDS Type 2>Attenuation Tank</SUDS Type 2><SUDS Measure Description 2>Underground Storage, 278m3, TWL 110.5m</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="35"><Development Name>Belmont Sector 1 (W)</Development Name><Location>Sandyford</Location><bldg__ctrl__no_>BC 1738</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Belmont,Sector 1, Aikens Village BC1738</Hyperlink><Consultant Engineers>DBFL</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>No</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>Swale</SUDS Type 1><SUDS Measure Description 1>"Details to be agreed with DLRCC"</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="36"><Development Name>Bishops Gate (Phase 1) (E)</Development Name><Location>Kilternan</Location><bldg__ctrl__no_>BC1810</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Bishops Gate BC1810</Hyperlink><Consultant Engineers>Rodger Mullarkey &amp; Associates</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>"Limiting flow to 25l/s, il=126.40. Provide a high level inlet/outlet 525 dia at il=128.00"</Hydrobrake Details><SUDS Type 1>GEO Light Storage Tank</SUDS Type 1><SUDS Measure Description 1>Off-line Underground Stormcell Tank</SUDS Measure Description 1><SUDS Type 2>Detention Basin</SUDS Type 2><SUDS Measure Description 2>Bed Level 127.75m OD</SUDS Measure Description 2><Additional SUDS xsi:nil="true" /><Additional SUDS Description xsi:nil="true" /><Comments>Existing spring to be diverted via 300 dia. 375mm x 450mm Culvert being diverted.</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="37"><Development Name>Bishops Gate (Phase 2) (E)</Development Name><Location>Kilternan</Location><bldg__ctrl__no_>BC1810</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Bishops Gate BC1810</Hyperlink><Consultant Engineers>Rodger Mullarkey &amp; Associates</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>Cellular Storage System</SUDS Type 1><SUDS Measure Description 1>200m3 Total</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="38"><Development Name>Brehon Chair (W)</Development Name><Location>Rathfarnham</Location><bldg__ctrl__no_>BC 1850</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Brehon Chair BC1850</Hyperlink><Consultant Engineers>Corrigan Hodnett Consulting</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 1.2 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>MC3500 Stormtech Attenuation Tank</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments xsi:nil="true" /><Comments - Additional Files xsi:nil="true" /></row>
<row _id="39"><Development Name>Brighton Wood (W)</Development Name><Location>Leopardstown</Location><bldg__ctrl__no_>BC1804</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Brighton Wood BC1804</Hyperlink><Consultant Engineers>Waterman Moylans</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_ xsi:nil="true" /><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>Multiple Swales</SUDS Type 1><SUDS Measure Description 1>Multiple Swales adjacent to roadways</SUDS Measure Description 1><SUDS Type 2>Pond to store M30 event/M30 to M100 storage in woodland area</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS xsi:nil="true" /><Additional SUDS Description xsi:nil="true" /><Comments>Dry ditch present, proprosal for ditch to drain into swale. Foul storage tank, not sure if it is being used.</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="40"><Development Name>Broadlands (E)</Development Name><Location>Glenageary</Location><bldg__ctrl__no_>BC 1801</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Broadlands BC1801</Hyperlink><Consultant Engineers>Donnachadh O'Brien &amp; Associates</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes Att. Tank 1</h_brake_1__y___n_><Hydrobrake Details>SW manhole with HRD, SHE-0090-3000-0500-3000 Flow control limited to 3.0 l/s, CL 59.37 /IL 57.70, (100mm Overflow IL 58.95) SW manhole with HRD, SHE-0090-3700-1100-3700 Flow control limited to 3.7 l/s, IL 58.35, (100mm Overflow IL 59.60)</Hydrobrake Details><SUDS Type 1>Pluvial Cube Attenuation Tank 1</SUDS Type 1><SUDS Measure Description 1>109m3 Storage IL 57.85m</SUDS Measure Description 1><SUDS Type 2>Pluvial Cube Attenuation Tank 2</SUDS Type 2><SUDS Measure Description 2>40m3 Storage IL 58.50m</SUDS Measure Description 2><Additional SUDS>Pluvial Cube Attenuation Tank 3</Additional SUDS><Additional SUDS Description>75m3 Storage IL 58.50m</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="41"><Development Name>Camberley Mews (W)</Development Name><Location>Churchtown</Location><bldg__ctrl__no_>BC 1808</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Camberley Mews BC1808</Hyperlink><Consultant Engineers>Barrett Mahony Con. Eng.</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 2.0 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Existing attenuation tank, unsized</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments xsi:nil="true" /><Comments - Additional Files xsi:nil="true" /></row>
<row _id="42"><Development Name>Carraig Bui (E)</Development Name><Location>Cabinteely</Location><bldg__ctrl__no_>BC 1852</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Carraig Bui BC1852</Hyperlink><Consultant Engineers>Lohan &amp; Donnelly</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>No</h_brake_1__y___n_><Hydrobrake Details>"Outfall MH, Flow Control Device at 8.77 l/s &amp; penstock"</Hydrobrake Details><SUDS Type 1>Stormtech SC-740</SUDS Type 1><SUDS Measure Description 1>"Attenuation Tank, min. volume 183m3" Further details on drawing</SUDS Measure Description 1><SUDS Type 2>Green Roof on apartment block</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Duplicate building control number with Glenageary Avenue</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="43"><Development Name>Castlecourt (W)</Development Name><Location>Churchtown</Location><bldg__ctrl__no_>BC 1817</bldg__ctrl__no_><Status>Additional Files - Complete</Status><Hyperlink>Castlecourt, Churchtown BC1817</Hyperlink><Consultant Engineers>Donnacadh O'Brien Con. Engs</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake Manhole Outflow Limited to 2 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tanks</SUDS Type 1><SUDS Measure Description 1>No details for size</SUDS Measure Description 1><SUDS Type 2>Yes</SUDS Type 2><SUDS Measure Description 2>95% void formed soakaway to serve individual houses in each garden, storage provided 9.5m3</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Partial File, no drainage drawings, survey notes have completed some details. Development has been named Castle Park</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="44"><Development Name>Clay Farm Phase 1 (W)</Development Name><Location>Ballyogan</Location><bldg__ctrl__no_>BC 1727</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Clay Farm BC1727</Hyperlink><Consultant Engineers>DBFL</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Multiple</h_brake_1__y___n_><Hydrobrake Details>Flow control device for catchment A 16.3 l/s. IL 94.52. Flow control device for catchment B 22.9 l/s. IL 94.52 Flow control device for catchment C 43.1 l/s. IL 92.72 Flow control device for catchment D 55.9 l/s.</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Surface water storage catchment A: Stormtech SC 740, Volume 108.2m3 (1:100 Year). IL 94.32m,TWL 95.375 Surface water storage catchment B: Stormtech SC 740, Volume 307.3m3 (1:100 Year). IL 93.24m,TWL 94.27</SUDS Measure Description 1><SUDS Type 2>Attenuation Tank</SUDS Type 2><SUDS Measure Description 2>Surface water storage catchment C: Stormtech SC 740, Volume 290.1m3 (1:100 Year). IL 92.18m, TWL 93.397 Surface water storage catchment D: Stormtech SC 740, Volume 506.8m3 (1:100 Year). IL 90.97m, TWL 92.39</SUDS Measure Description 2><Additional SUDS>Swales Bioretention Areas</Additional SUDS><Additional SUDS Description>Multiple Swales Multiple Retention Areas</Additional SUDS Description><Comments>Additional details on drawings</Comments><Comments - Additional Files>Some issues with wayleaves and taken in charge drawings.</Comments - Additional Files></row>
<row _id="45"><Development Name>Clay Farm Phase 2 (W)</Development Name><Location>Ballyogan</Location><bldg__ctrl__no_>BC 1727</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Clay Farm BC1727</Hyperlink><Consultant Engineers>DBFL</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Multiple</h_brake_1__y___n_><Hydrobrake Details>Flow control device for catchment A 16.3 l/s, Flow control device for catchment B 8.6 l/s, Flow control device for catchment C 39.5 l/s, Flow control device for catchment D 13.6 l/s, Flow control device for catchment E 28.8 l/s, Flow control device for catchment F 23.5 l/s, Flow control device for catchment G 18.3 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Surface water storage catchment A: Stormtech SC 780, Volume 689m3 (1:100 Year). IL 98.50m Surface water storage catchment B: Stormtech MC3500, Volume 1105m3 (1:100 Year). IL 101.81m, TWL 103.52 Surface water storage catchment C: Stormtech MC3500, Volume 506m3 (1:100 Year). IL 95.30m, TWL 96.52</SUDS Measure Description 1><SUDS Type 2>Attenuation Tank</SUDS Type 2><SUDS Measure Description 2>Surface water storage catchment D: Stormtech MC3500, Volume 1256m3 (1:100 Year). IL 103.00m Surface water storage catchment E: Stormtech MC3500, Volume 568m3 (1:100 Year). IL 92.80m, TWL 94.27 Surface water storage catchment F: Stormtech MC3500, Volume 366m3 (1:100 Year). IL 95.90m, TWL 97.34 Surface water storage catchment G: Stormtech MC3500, Volume 1131m3 (1:100 Year). IL 101.3m, TWL 102.58</SUDS Measure Description 2><Additional SUDS>Swales Bioretention Areas</Additional SUDS><Additional SUDS Description>Multiple Swales Multiple Retention Areas</Additional SUDS Description><Comments>Additional details on drawings</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="46"><Development Name>Clonkeen Road (E)</Development Name><Location>Blackrock</Location><bldg__ctrl__no_>BC 1793</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Clonkeen Road BC1793</Hyperlink><Consultant Engineers>O'Connor Sutton Cronin</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Q Max 0.6 l/s, Oriface=25mm</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Concrete Storage Tank, 16m x 10m x 1m, 199m3 Storage, CL=39.265, TWL=38.465, IL=37.265</SUDS Measure Description 1><SUDS Type 2>Interception Storage</SUDS Type 2><SUDS Measure Description 2>ESS Pluvial Cube, Storage 31.81m3, 5.5m x 6.0m x 1.075m</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="47"><Development Name>Cluain Shee</Development Name><Location>Aikens Village</Location><bldg__ctrl__no_>BC1485B</bldg__ctrl__no_><Status>TIC Files - Complete</Status><Hyperlink>Cluain Shee BC1485B</Hyperlink><Consultant Engineers>Terry &amp; O'Flanagan</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>S0 Hydrobrake, Cl 113.27, IL109.29</Hydrobrake Details><SUDS Type 1>Attenuation Area</SUDS Type 1><SUDS Measure Description 1>Attenuation Area Storage Capacity = Circa 1100m. Cu</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Details taken from TIC drawings dated September 2007, D121-1002</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="48"><Development Name>Cualanor (E)</Development Name><Location>Aikens Village</Location><bldg__ctrl__no_>BC 1779</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Cualanor BC1779</Hyperlink><Consultant Engineers>Waterman Moylans</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Y</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake IL 27.60/CL 32.00. Allowable Discharge 19.8 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>"Online Surface Water Attenuation Tank (CL 31.50) 1610m x 2.00 max water Level providing 3220m3 of storage"</SUDS Measure Description 1><SUDS Type 2>Detention Basin</SUDS Type 2><SUDS Measure Description 2>Attenuation tank overflows to detention basin.</SUDS Measure Description 2><Additional SUDS>2 X bio-retention areas at bowling club</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="49"><Development Name>Dunedin (E)</Development Name><Location>Monkstown</Location><bldg__ctrl__no_>BC 1833</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Dunedin BC1833</Hyperlink><Consultant Engineers>D.C. Turley and Associates</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>No</h_brake_1__y___n_><Hydrobrake Details>Outfall manhole with oriface plate 33dia max, discharge limited to 2 l/s</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>No attenuation</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="50"><Development Name>Eaton Brae House (E)</Development Name><Location>Windy Arbour</Location><bldg__ctrl__no_>BC 1856</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Eaton Brae House BC1856</Hyperlink><Consultant Engineers>Dean Turner Associates</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Y</h_brake_1__y___n_><Hydrobrake Details>Penstock valve and flow control device @ 4l/s with min. 75mm morifice and bypass door</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>"Surface Water Attenuation System Wavin Aquacell Size 37.5M Long X 4m Wide X 0.8m Deep. (Volume 120m)"</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>No connection shown from attenuation tank to pipe work</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="51"><Development Name>Ely Place</Development Name><Location>Rathfarnham</Location><bldg__ctrl__no_>BC 1712</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Ely Place BC1712</Hyperlink><Consultant Engineers>Burroughs</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>"Manhole S1/4 to house orifice control perforated riser for 1/1, 1/30 &amp; 1/100 storm flows.</Hydrobrake Details><SUDS Type 1>Under-ground storage tank</SUDS Type 1><SUDS Measure Description 1>150m3 of Q100 storm storage to be provided in underground storage tank. CL 49.92/IL 48.35</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="52"><Development Name>Enderly</Development Name><Location>Dalkey</Location><bldg__ctrl__no_>BC 1782</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Enderly, Dalkey BC1782</Hyperlink><Consultant Engineers>-</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>"SW MH No. SW6 to incorporate flow control device - hydrobrake or similar approved to restrict flow to 4.6 l/s sec max."</Hydrobrake Details><SUDS Type 1>Stormtech</SUDS Type 1><SUDS Measure Description 1>"Stormtech Surface Water Attenuation tank chamber system Ref. MC-3500 (or similar) with 300mm of CL505 stone (min. 43% voids) above and below chambers"</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Discharges to combined sewer? Duplicate BC number with The Cottages, Tivoli Road</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="53"><Development Name>Fernbank House (W)</Development Name><Location>Churchtown</Location><bldg__ctrl__no_>BC 1816</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Fernbank House BC1816</Hyperlink><Consultant Engineers>DBFL</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 3.2 l/s Hydrobrake, Discharge Limited to 2.1 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Stormbloc, Volume 718m3, IL 45.82m, TWL 47.80m</SUDS Measure Description 1><SUDS Type 2>Attenuation Tank</SUDS Type 2><SUDS Measure Description 2>Stormbloc, Volume 148m3, IL 45.56m, TWL 46.22m</SUDS Measure Description 2><Additional SUDS>Green Roof Swale</Additional SUDS><Additional SUDS Description>Multiple green roof, Area not provided Dry Swale 58m x 2m x 0.5m</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="54"><Development Name>Glenart Avenue</Development Name><Location>Blackrock</Location><bldg__ctrl__no_>BC 1821</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Glenart Avenue BC1821</Hyperlink><Consultant Engineers>Cronin &amp; Sutton Consulting</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Oriface Plate Flow Restricter to Limit Outflow to 2l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Attenuation Tank per property x 4</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="55"><Development Name>Glensavage</Development Name><Location>Blackrock</Location><bldg__ctrl__no_>BC 1860</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Glensavage Blackrock BC1860</Hyperlink><Consultant Engineers>CS Consulting Group</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Flow Control Manhole, discharge limited to 3.4 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Pre-cast attenuation tank, 180m3, 0.9m Deep</SUDS Measure Description 1><SUDS Type 2>Storage Basin</SUDS Type 2><SUDS Measure Description 2>Basin with 1:2 side slopes to cater for emergency storm storage</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="56"><Development Name>Grange Hill (W)</Development Name><Location>Ballinteer</Location><bldg__ctrl__no_>BC 1759</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Grange Hill BC1759</Hyperlink><Consultant Engineers>AKM Consultants</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake IL 115.80/CL 118.10</Hydrobrake Details><SUDS Type 1>Concrete Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>150m3</SUDS Measure Description 1><SUDS Type 2>Detention Basin</SUDS Type 2><SUDS Measure Description 2>IL 117.80</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="57"><Development Name>Hawthorn (W)</Development Name><Location>Clonskeagh</Location><bldg__ctrl__no_>BC 1803</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Hawthorn BC1803</Hyperlink><Consultant Engineers>Downes Associates</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Flow Control Manhole restricted to 8.29 l/s</Hydrobrake Details><SUDS Type 1>Stormtech SC-790 (740?)</SUDS Type 1><SUDS Measure Description 1>STORMTECH SC-790 ATTENUATION STORAGE UNITS OR SIMILAR APPROVED I.L = 30.515, Volume = 346m2</SUDS Measure Description 1><SUDS Type 2>Detention Basin</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Seems to be a combination of detention basin and Stormtech SC-740</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="58"><Development Name>Inglenook (E)</Development Name><Location>Carrickmines</Location><bldg__ctrl__no_>BC 1826</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Inglenook BC1826</Hyperlink><Consultant Engineers>D. Fallon Consulting Engineers</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Discharge Limited to 3.3 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Stormtech SC-740, 177m3</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="59"><Development Name>Knockrabro (W)</Development Name><Location>Goatstown</Location><bldg__ctrl__no_>BC 1792</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Knocknabro BC1792</Hyperlink><Consultant Engineers>DBFL</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake Optimum Flow Device Manhole 13 l/s @1.6m</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Stormtech mc3500, 9 Rows x 7 Chambers, Volume 344m3, IL 59.263</SUDS Measure Description 1><SUDS Type 2>Swale</SUDS Type 2><SUDS Measure Description 2>Bio-retention swale 60m x 5m x 0.5m deep, 61m3</SUDS Measure Description 2><Additional SUDS>Green Roof Bioretention Areas</Additional SUDS><Additional SUDS Description>4 x Green Roof, Approx 877m2 Multiple Retention Areas</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="60"><Development Name>Northumberland Close (E)</Development Name><Location>Dun Laoghaire</Location><bldg__ctrl__no_>BC 1838</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>Northumberland Close BC1838</Hyperlink><Consultant Engineers>Corrigan Hodnett Consulting</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>-</h_brake_1__y___n_><Hydrobrake Details>-</Hydrobrake Details><SUDS Type 1>-</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Some SUDS measures on drawing. No details identified</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="61"><Development Name>Rockville House (W)</Development Name><Location>Glenamuck</Location><bldg__ctrl__no_>BC 1843</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Rockville House BC1843</Hyperlink><Consultant Engineers>Atkins</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Vortex Flow Control Device to limit discharge rate 4.4 l/s during 1 in 100 year event</Hydrobrake Details><SUDS Type 1>Swale</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>No details for the swale (volume, size)</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="62"><Development Name>Shandon Park (E)</Development Name><Location>Monkstown</Location><bldg__ctrl__no_>BC 1844</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Shandon Park BC1844</Hyperlink><Consultant Engineers>Killiney Design Associates</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Y</h_brake_1__y___n_><Hydrobrake Details>Flow control manhole. Discharge to be 2.0 l/s/hectare</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Aquacell Attenuation Tank (5.0m x 3.0m x 1.0m)</SUDS Measure Description 1><SUDS Type 2>Attenuation Tank</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>No details on second attenuation tank</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="63"><Development Name>Sliverton (W)</Development Name><Location>Rathfarnham</Location><bldg__ctrl__no_>BC 1781</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Sliverton BC1781</Hyperlink><Consultant Engineers>O'Connor Sutton Cronin</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Y</h_brake_1__y___n_><Hydrobrake Details>1200mm, CL 114.511m, Hydrobrake MH Limited to 2.7 l/s, 450mm(d) Catchpit &amp; Backdrop facility S14, 1200mm, CL 112.300m, Hydrobrake MH, Limited to 3.2l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>STORAGE TANK #1, Stormtech SC 740 Series Total Attenuation Storage Provided - 57.07m3 with 200mm layer of OCCR above tank.</SUDS Measure Description 1><SUDS Type 2>Attenuation Tank</SUDS Type 2><SUDS Measure Description 2>STORAGE TANK #2 Stormtech SC 740 Series Total Attenuation Storage Provided - 70.70m3 with 200mm layer of OCCR above tank.</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Additonal details on drawing number N210-H01</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="64"><Development Name>St Paul's Adelaides Rd (E)</Development Name><Location>Glenageary</Location><bldg__ctrl__no_>BC 1829</bldg__ctrl__no_><Status>Incomplete</Status><Hyperlink>St Paul's Adelaides Rd. BC1829</Hyperlink><Consultant Engineers>Kavanagh Burke Con. Engs</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 2.0 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Details for attenuation systems are off the page.</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>No attenuation details</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="65"><Development Name>Stanford Park (E)</Development Name><Location>Foxrock</Location><bldg__ctrl__no_>BC 1818</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Stanford Park BC1818</Hyperlink><Consultant Engineers>Conor Furey &amp; Associates Ltd</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>"SW 1.6, Hydrobrake MH. CL 73.33m, IL 70.528m</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Stormtech MC4500, 184m3 Storage Provided. CL 73.28m, TWL 72.67m (&gt;500MM below lowest FFL). IL 71.146, OL 71.146</SUDS Measure Description 1><SUDS Type 2>Attenuation Tank</SUDS Type 2><SUDS Measure Description 2>Stormtech MC4500, 52m3 Storage Provided. CL 72.09m, TWL 71.12m (&gt;500mm below dwelling FFL). IL 71.12</SUDS Measure Description 2><Additional SUDS>Infiltration Swale</Additional SUDS><Additional SUDS Description>Side Slope 1:3 2.9m(W) top, 0.5m (W) bot 13m (L) x 0.4m (DP)</Additional SUDS Description><Comments xsi:nil="true" /><Comments - Additional Files xsi:nil="true" /></row>
<row _id="66"><Development Name>Stepaside Park (Phase 2) (E)</Development Name><Location>Stepaside</Location><bldg__ctrl__no_>BC 1379.1</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Stepaside Park BC1379.1</Hyperlink><Consultant Engineers>DBFL</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Flow Control Manhole restricted to 52 l/s. Design Head 2.46m</Hydrobrake Details><SUDS Type 1>Swale 1</SUDS Type 1><SUDS Measure Description 1>-</SUDS Measure Description 1><SUDS Type 2>Detention Basin</SUDS Type 2><SUDS Measure Description 2>100 yr Flood Volume 600m3</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Filter sewer</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="67"><Development Name>Taney Nurseries (W)</Development Name><Location>Dundrum</Location><bldg__ctrl__no_>BC 1825</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Taney Nurseries BC1825</Hyperlink><Consultant Engineers>Mc Kenna Pearce Practice</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 4.73 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Aquacell Attenuation Tank (20.0m x 4.5m x 1.2m). Volume 102m3</SUDS Measure Description 1><SUDS Type 2>Soakaway</SUDS Type 2><SUDS Measure Description 2>7 x Aquacell Soakaway, 12m x 1.5m x 0.8m, 1 x Aquacell Soakaway, 14m x 1.5m x 0.8m</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments xsi:nil="true" /><Comments - Additional Files xsi:nil="true" /></row>
<row _id="68"><Development Name>The Grove (W)</Development Name><Location>Goatstown</Location><bldg__ctrl__no_>BC 1764</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>The Grove BC1764</Hyperlink><Consultant Engineers>DBFL</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Flow Control Manhole Limiting Outflow to 5 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Attenuation storage using stormtech sc 740 units. Total volume provided = 160m3, IL 38.70m</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="69"><Development Name>The Rise (W)</Development Name><Location>Mount Merrion</Location><bldg__ctrl__no_>BC 1839</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>The Rise BC1839</Hyperlink><Consultant Engineers>Laurence Buckley Con. Eng</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 2.0 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>JFC Hydro Chamber or Similar Approved</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>Very little information on SUDS measures</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="70"><Development Name>Westminster Wood (E)</Development Name><Location>Foxrock</Location><bldg__ctrl__no_>BC 1837</bldg__ctrl__no_><Status>Complete</Status><Hyperlink>Westminster Wood BC1837</Hyperlink><Consultant Engineers>J.B. Barrys C. Engs</Consultant Engineers><suds_built__y_n_>Yes</suds_built__y_n_><h_brake_1__y___n_>Yes</h_brake_1__y___n_><Hydrobrake Details>Hydrobrake, Discharge Limited to 2.0 l/s</Hydrobrake Details><SUDS Type 1>Attenuation Tank</SUDS Type 1><SUDS Measure Description 1>Pluvial Cube, Volume 230m3</SUDS Measure Description 1><SUDS Type 2>-</SUDS Type 2><SUDS Measure Description 2>-</SUDS Measure Description 2><Additional SUDS>-</Additional SUDS><Additional SUDS Description>-</Additional SUDS Description><Comments>-</Comments><Comments - Additional Files xsi:nil="true" /></row>
<row _id="71"><Development Name>Ashwood Farm (Not Constructed)</Development Name><Location xsi:nil="true" /><bldg__ctrl__no_ xsi:nil="true" /><Status xsi:nil="true" /><Hyperlink xsi:nil="true" /><Consultant Engineers xsi:nil="true" /><suds_built__y_n_ xsi:nil="true" /><h_brake_1__y___n_ xsi:nil="true" /><Hydrobrake Details xsi:nil="true" /><SUDS Type 1 xsi:nil="true" /><SUDS Measure Description 1 xsi:nil="true" /><SUDS Type 2 xsi:nil="true" /><SUDS Measure Description 2 xsi:nil="true" /><Additional SUDS xsi:nil="true" /><Additional SUDS Description xsi:nil="true" /><Comments xsi:nil="true" /><Comments - Additional Files xsi:nil="true" /></row>
<row _id="72"><Development Name>Kenmay</Development Name><Location xsi:nil="true" /><bldg__ctrl__no_ xsi:nil="true" /><Status>Incomplete</Status><Hyperlink xsi:nil="true" /><Consultant Engineers xsi:nil="true" /><suds_built__y_n_ xsi:nil="true" /><h_brake_1__y___n_ xsi:nil="true" /><Hydrobrake Details xsi:nil="true" /><SUDS Type 1 xsi:nil="true" /><SUDS Measure Description 1 xsi:nil="true" /><SUDS Type 2 xsi:nil="true" /><SUDS Measure Description 2 xsi:nil="true" /><Additional SUDS xsi:nil="true" /><Additional SUDS Description xsi:nil="true" /><Comments xsi:nil="true" /><Comments - Additional Files xsi:nil="true" /></row>
<row _id="73"><Development Name>Priory Drive</Development Name><Location xsi:nil="true" /><bldg__ctrl__no_ xsi:nil="true" /><Status>Incomplete</Status><Hyperlink xsi:nil="true" /><Consultant Engineers xsi:nil="true" /><suds_built__y_n_ xsi:nil="true" /><h_brake_1__y___n_ xsi:nil="true" /><Hydrobrake Details xsi:nil="true" /><SUDS Type 1 xsi:nil="true" /><SUDS Measure Description 1 xsi:nil="true" /><SUDS Type 2 xsi:nil="true" /><SUDS Measure Description 2 xsi:nil="true" /><Additional SUDS xsi:nil="true" /><Additional SUDS Description xsi:nil="true" /><Comments>Mislabelled?</Comments><Comments - Additional Files xsi:nil="true" /></row>
</data>