<data xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<row _id="1"><Database Reference>1</Database Reference><Location>Beaumount Co-location </Location><Land use>Hospital</Land use><National Grid Reference   X>318236.438</National Grid Reference   X><National Grid Reference Y>239272.328</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\1083-08 Beaumont Co Location Hospital, Beaumont, Dublin 9,</File/Consent Reference><Status (constructed or otherwise)>Planning</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private hospital</Maintained by><contributing area (both permeable and impermeable) m2>15000</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, permeable paving</Type of Device><Reason for Installation>Planning conditions</Reason for Installation><Physical Features,  (Shape, size, etc)>20 no permeable paved car spaces, 25m3 tank</Physical Features,  (Shape, size, etc)><Outflow Flow limit>hydrobrake with 2ls flow</Outflow Flow limit><Ecological Features (Plant life)>n/a</Ecological Features (Plant life)><Water Quality /></row>
<row _id="2"><Database Reference>2</Database Reference><Location>BRL</Location><Land use>mixed use development</Land use><National Grid Reference   X>314283.326</National Grid Reference   X><National Grid Reference Y>239936.2</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\BRL</File/Consent Reference><Status (constructed or otherwise)>under construction</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Public</Ownership><Maintained by>Public (once its taken in charge)</Maintained by><contributing area (both permeable and impermeable) m2>1500000</contributing area (both permeable and impermeable) m2><Type of Device>Detention  pond, permeable paving, swales, Green roofs</Type of Device><Reason for Installation>Planning conditions</Reason for Installation><Physical Features,  (Shape, size, etc)>£ Retention ponds 32,000m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>15.8</Outflow Flow limit><Ecological Features (Plant life)>Green Roof on rec centre</Ecological Features (Plant life)><Water Quality /></row>
<row _id="3"><Database Reference>3</Database Reference><Location>Pellettown</Location><Land use>Mixed use development</Land use><National Grid Reference   X>312193.438</National Grid Reference   X><National Grid Reference Y>237547.719</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\3306-08 Block K of Pelletstown, Ashtown, Dublin 11</File/Consent Reference><Status (constructed or otherwise)>under construction</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Public (once its taken in charge)</Ownership><Maintained by>Public (once its taken in charge)</Maintained by><contributing area (both permeable and impermeable) m2>400000</contributing area (both permeable and impermeable) m2><Type of Device>Detention  pond, permeable paving, swales, </Type of Device><Reason for Installation>Planning conditions</Reason for Installation><Physical Features,  (Shape, size, etc)>retention pond:10000m3, 70m long swale Over 100 permeable paving car paving spaces </Physical Features,  (Shape, size, etc)><Outflow Flow limit>4.9</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="4"><Database Reference>4</Database Reference><Location>Lansdowne stadium</Location><Land use>Stadium</Land use><National Grid Reference   X>318172.354</National Grid Reference   X><National Grid Reference Y>233039.129</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5692-06 7 Landsdown trc</File/Consent Reference><Status (constructed or otherwise)>Planning</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brown field</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>private</Maintained by><contributing area (both permeable and impermeable) m2>50000</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, permeable paving: </Type of Device><Reason for Installation>Planning conditions</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation Tank:24m3 Permeable paving:5289m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Flow limit related to flow in river dodder</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="5"><Database Reference>5</Database Reference><Location>St Pats drumcondra</Location><Land use>College</Land use><National Grid Reference   X>316153.832</National Grid Reference   X><National Grid Reference Y>237080.552</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\4245-08 St Patricks College, Drumcondra\</File/Consent Reference><Status (constructed or otherwise)>Planning</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brown field</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>private</Maintained by><contributing area (both permeable and impermeable) m2>38415</contributing area (both permeable and impermeable) m2><Type of Device>Green Roof, Permeable paving, Attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank: 40m3, Green roofs: n/a, Permeable paving: n/a</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life)>Green Roof</Ecological Features (Plant life)><Water Quality /></row>
<row _id="6"><Database Reference>6</Database Reference><Location>Aldi Store Finglas</Location><Land use>Retail</Land use><National Grid Reference   X>312822.438</National Grid Reference   X><National Grid Reference Y>240030.219</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\4474-08 Extension to Aldi Store, Finglas</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brown field</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>10455</contributing area (both permeable and impermeable) m2><Type of Device>Permeable paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving:3000m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="7"><Database Reference>7</Database Reference><Location>St Vincents hospice  fairview</Location><Land use>Hospital</Land use><National Grid Reference   X>316937.045</National Grid Reference   X><National Grid Reference Y>236640</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\4483-08 Fairview CNU</File/Consent Reference><Status (constructed or otherwise)>Planning</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>13482</contributing area (both permeable and impermeable) m2><Type of Device>Permeable paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving: 1600m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="8"><Database Reference>8</Database Reference><Location>Victoria Lane</Location><Land use>3 houses</Land use><National Grid Reference   X>314417.477</National Grid Reference   X><National Grid Reference Y>231566.982</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\1145-07 Victoria Lane</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>225</contributing area (both permeable and impermeable) m2><Type of Device>Permeable paving And Hydro Brake</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Driveway</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="9"><Database Reference>9</Database Reference><Location>Eastmoreland Lane</Location><Land use>Private Development 20m*6m</Land use><National Grid Reference   X>317042.818</National Grid Reference   X><National Grid Reference Y>232895.384</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\1152-07 20 upper baggot st Dublin 4</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>120</contributing area (both permeable and impermeable) m2><Type of Device>Green Roof, Permeable paving,</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>0.022ha permeable paving +green roof</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life)>Green roof</Ecological Features (Plant life)><Water Quality /></row>
<row _id="10"><Database Reference>10</Database Reference><Location>39A Violet Hill Drive</Location><Land use>Single house</Land use><National Grid Reference   X>314202.938</National Grid Reference   X><National Grid Reference Y>237562.172</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\1242-07 39A Violet Hill Drive, Dublin 11</File/Consent Reference><Status (constructed or otherwise)>Planning</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>320</contributing area (both permeable and impermeable) m2><Type of Device>Filter drains</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>three 300mm dia x 10m long storage pipes</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="11"><Database Reference>11</Database Reference><Location>274 North Circular Road</Location><Land use>Apartments</Land use><National Grid Reference   X>314662</National Grid Reference   X><National Grid Reference Y>235597</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\1384-07 274 North Circular Road</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>14325</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank 71m*2.5m*0.625m</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="12"><Database Reference>12</Database Reference><Location>Ballsbridge Avenue</Location><Land use>4 houses</Land use><National Grid Reference   X>318000.031</National Grid Reference   X><National Grid Reference Y>232560.484</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\1426-07 Ballsbridge Avenue</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>225</contributing area (both permeable and impermeable) m2><Type of Device>Filter Drain + rain Water harvesting</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>4*15m*100mm filter drains and 4x3m3 rain water harvesting tanks</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="13"><Database Reference>13</Database Reference><Location>288 Bannow Road, Cabra</Location><Land use>5 apartment blocks</Land use><National Grid Reference   X>319970.971</National Grid Reference   X><National Grid Reference Y>240522.313</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\1509-07 288 Bannow Road, Cabra</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>6205</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank:0.85 dp x 18m long x 4.35 wide</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="14"><Database Reference>14</Database Reference><Location>40 to 42 Hill Street Dublin 1</Location><Land use>apartment blocks</Land use><National Grid Reference   X>315940.696</National Grid Reference   X><National Grid Reference Y>235190.823</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2199-07 40 to 42 Hill Street Dublin 1</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>600</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank:20m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="15"><Database Reference>15</Database Reference><Location> old shell garage site, coo LOCK village, coo LOCK, Dublin 5</Location><Land use>three storey mixed use development comprising  residential and commercial use </Land use><National Grid Reference   X>319742.906</National Grid Reference   X><National Grid Reference Y>238931.219</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2277-07 old shell garage site, coo LOCK village, coo LOCK, Dublin 5</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>1850</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank:12.00mX2.750mX.600m</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="16"><Database Reference>16</Database Reference><Location>113 Phibsborough Road  Royal Canal Bank Dublin 7</Location><Land use>4 storey over basement mixed development with 3, 1 bedroom and 4, 2 bedroom apartments above ground level, retail unit over basement car park </Land use><National Grid Reference   X>318225.156</National Grid Reference   X><National Grid Reference Y>236384.844</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2350-07 113 Phibsborough Road  Royal Canal Bank Dublin 7</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>240</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank:10m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="17"><Database Reference>17</Database Reference><Location>27 Temple Road Dartry</Location><Land use>single house</Land use><National Grid Reference   X>316194.007</National Grid Reference   X><National Grid Reference Y>230277.14</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2410-07 27 Temple Road Dartry</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>45</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Soakaway:2.4.X1.5X1m</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="18"><Database Reference>18</Database Reference><Location>Fairview park sports ground</Location><Land use>Sport ground</Land use><National Grid Reference   X>317712.727</National Grid Reference   X><National Grid Reference Y>236300.181</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2506-07 Fairview Park Sports Centre</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>DCC parks</Maintained by><contributing area (both permeable and impermeable) m2>720</contributing area (both permeable and impermeable) m2><Type of Device>online storage</Type of Device><Reason for Installation /><Physical Features,  (Shape, size, etc)>online storage 2X600mm pipes</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="19"><Database Reference>19</Database Reference><Location> Elm Mount Avenue, Beaumont, Dublin 9</Location><Land use>a new two storey house </Land use><National Grid Reference   X>317900.531</National Grid Reference   X><National Grid Reference Y>238186.453</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2567-07 86 Elm Mount Avenue, Beaumont, Dublin 9</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>351</contributing area (both permeable and impermeable) m2><Type of Device>permeable paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>permeable paving :30m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="20"><Database Reference>20</Database Reference><Location>Edenmore Avenue</Location><Land use>5 Houses and Scout Den</Land use><National Grid Reference   X>321020.469</National Grid Reference   X><National Grid Reference Y>239193.516</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2740-07 Housing and Scout Den at Edenmore Avenue, Coolock</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>1023</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation Tank:6.6X2.35X1.1m</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="21"><Database Reference>21</Database Reference><Location>106a and 107 North King Street</Location><Land use /><National Grid Reference   X>314477.313</National Grid Reference   X><National Grid Reference Y>234689.438</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2903-07 106a and 107 North King Street</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>120</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank:4.6m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="22"><Database Reference>22</Database Reference><Location>40a Maryvile Rd Raheny</Location><Land use>2 house</Land use><National Grid Reference   X>320818.997</National Grid Reference   X><National Grid Reference Y>237780.895</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2947-07 40A Maryville Road, Raheny</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>500</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Soakaway:2.6.X8X6m</Physical Features,  (Shape, size, etc)><Outflow Flow limit /><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="23"><Database Reference>23</Database Reference><Location>Beneavin Lodge, Beneavin Rd</Location><Land use>Nursing home extension</Land use><National Grid Reference   X>314208</National Grid Reference   X><National Grid Reference Y>238971.297</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2989-07 Beneavin Lodge</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>4400</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank:75m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="24"><Database Reference>24</Database Reference><Location>233 raheny road</Location><Land use>new two-storey four (4) bedroom detached house,</Land use><National Grid Reference   X>321786.844</National Grid Reference   X><National Grid Reference Y>239287.609</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\3051-07 233 Raheny Road Raheny Dublin 5</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>225</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank:2.75x2x0.45</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="25"><Database Reference>25</Database Reference><Location>22-24 sheriff st upper</Location><Land use>7 storey office  building</Land use><National Grid Reference   X>317512.219</National Grid Reference   X><National Grid Reference Y>234783.828</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\3115-07 The Stockyard 22-24 Sheriff Street Upper Dublin 3</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>630</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank:37m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>pumped flow 3l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="26"><Database Reference>26</Database Reference><Location>31-36 Ormond quay upper</Location><Land use>5 storey mixed development</Land use><National Grid Reference   X>315169.188</National Grid Reference   X><National Grid Reference Y>234207.125</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\3367-07 31-36 Ormond Quay Upper</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>1175</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank, </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank: 54.3m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 3.4l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="27"><Database Reference>27</Database Reference><Location>coolock lane</Location><Land use>two storey twelve classroom plus ancillary accommodation school building</Land use><National Grid Reference   X>317751.25</National Grid Reference   X><National Grid Reference Y>239862.438</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\3870-07 Gaelscoil Cholmcille off Coolock Lane Adjacent To The Astro Park Football Club And Castletimon Road Coolock Arthur Mallon Architect Dublin 17</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>School</Maintained by><contributing area (both permeable and impermeable) m2>1575</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaway: 10x12.5x0.8 m</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="28"><Database Reference>28</Database Reference><Location>5 harcourt st</Location><Land use>new seven storey hotel building</Land use><National Grid Reference   X>316514.375</National Grid Reference   X><National Grid Reference Y>233818.153</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\3992-07 St Stephens Green Hotel Extension</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>2500</contributing area (both permeable and impermeable) m2><Type of Device>Permeable paving  on roof and rain water harvesting tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving :175m2  Rain water harvesting tank 1.5 m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="29"><Database Reference>29</Database Reference><Location>95a gracefield rd</Location><Land use>new house</Land use><National Grid Reference   X>319978.063</National Grid Reference   X><National Grid Reference Y>238414.156</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\4453-07 96 gracefield road Artane Dublin 5</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>160</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank &amp; rain water harvesting tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank:1m3 rain water harvesting tank:1m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="30"><Database Reference>30</Database Reference><Location>3 St Brendan's Av Coolock D15</Location><Land use>New House</Land use><National Grid Reference   X>319598.906</National Grid Reference   X><National Grid Reference Y>238504.125</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\4738-07 3 St Brendan's Avenue, Coolock, Dublin 5</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>407</contributing area (both permeable and impermeable) m2><Type of Device>Rain water harvesting and attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Rain water harvesting tank:3.8m3  Attenuation tank .7m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Overflow to soakaway Capacity N/A</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="31"><Database Reference>31</Database Reference><Location>33&amp; 34 Kenilworth Square west</Location><Land use>4 house development</Land use><National Grid Reference   X>314832.4</National Grid Reference   X><National Grid Reference Y>231073.2</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\5042-07 33&amp;34 Kenilworth Square West</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>432</contributing area (both permeable and impermeable) m2><Type of Device>Permeable Paving &amp;Attenuation Tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable Paving: 102m2 &amp; attenuation Tank;8.8m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="32"><Database Reference>32</Database Reference><Location>Holles St Hospital</Location><Land use>Hospital redevelopment</Land use><National Grid Reference   X>316904.632</National Grid Reference   X><National Grid Reference Y>233551.362</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\5091-07 Holles Street Hospital Development</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>900</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation pipe</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation pipe 9m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="33"><Database Reference>33</Database Reference><Location>48a Willows park</Location><Land use>2 houses</Land use><National Grid Reference   X>314536.826</National Grid Reference   X><National Grid Reference Y>239483.072</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\5399-07 48 Willow Park Road, Glasnevin, Dublin 11</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>775</contributing area (both permeable and impermeable) m2><Type of Device>2 soakaways</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaways:N/A</Physical Features,  (Shape, size, etc)><Outflow Flow limit /><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="34"><Database Reference>34</Database Reference><Location>North Brunswick st hostel</Location><Land use>hostel extension</Land use><National Grid Reference   X>314926.797</National Grid Reference   X><National Grid Reference Y>234885.075</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\5839-07 Morning Star Hostel</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>955</contributing area (both permeable and impermeable) m2><Type of Device>attenuation drain</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation drain 3.75m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit /><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="35"><Database Reference>35</Database Reference><Location>Smithfield, Riverview house</Location><Land use>7 to 11 storey office  building</Land use><National Grid Reference   X>315086.309</National Grid Reference   X><National Grid Reference Y>234338.621</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\6171-07 River House Chancery Street</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>3600</contributing area (both permeable and impermeable) m2><Type of Device>permeable paving + attenuation tan below, Green roof</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving 100m2+ attenuation tank 34m3 + green roofs 85m2+118m2+120m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake .5l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="36"><Database Reference>36</Database Reference><Location>11-13 brookwod terrace</Location><Land use>4 new  houses</Land use><National Grid Reference   X>320314.906</National Grid Reference   X><National Grid Reference Y>238250.359</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\6235-07 11 &amp; 13 Brookwood Crescent, Artane</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>1107</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaway:18.8m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="37"><Database Reference>37</Database Reference><Location>68 kincora court</Location><Land use>Single house</Land use><National Grid Reference   X>320661.656</National Grid Reference   X><National Grid Reference Y>235922.609</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\6686-07 69 Kincora Court, Clontarf</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>108</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaway:38.4m4</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="38"><Database Reference>38</Database Reference><Location>62 Ballygal Rd east</Location><Land use>4 houses</Land use><National Grid Reference   X>314709.656</National Grid Reference   X><National Grid Reference Y>238165.266</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\1432-08 Rear 60 62 Ballygall Road East, Finglas, Dublin 11</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>600</contributing area (both permeable and impermeable) m2><Type of Device>3 Soakaways</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>3 Soakaways: 7m3 each</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="39"><Database Reference>39</Database Reference><Location>51-50 O'Connell st </Location><Land use>mixed use development</Land use><National Grid Reference   X>315781.175</National Grid Reference   X><National Grid Reference Y>234897.341</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\2726-08 40-42 O'Connell Street, Dublin 1</File/Consent Reference><Status (constructed or otherwise)>under construction</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>2400</contributing area (both permeable and impermeable) m2><Type of Device>Permeable paving and online attenuation</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving1710 m2 , online attenuation 25m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="40"><Database Reference>40</Database Reference><Location> Harrison Row</Location><Land use>2 houses</Land use><National Grid Reference   X>314865.267</National Grid Reference   X><National Grid Reference Y>230461.944</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\2888-08</File/Consent Reference><Status (constructed or otherwise)>under construction</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>192</contributing area (both permeable and impermeable) m2><Type of Device>2 Attenuation/ rainwater tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>2 Attenuation/ rainwater tank: 2m3 each</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="41"><Database Reference>41</Database Reference><Location> Harrison Row</Location><Land use>3 Houses</Land use><National Grid Reference   X>314854.013</National Grid Reference   X><National Grid Reference Y>230456.436</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\3187-08 Harrison Row</File/Consent Reference><Status (constructed or otherwise)>under construction</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>360</contributing area (both permeable and impermeable) m2><Type of Device>3 Attenuation/ rainwater tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>3 Attenuation/ rainwater tank: 2m3 each</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="42"><Database Reference>42</Database Reference><Location>snow drop walk</Location><Land use>sport changing area</Land use><National Grid Reference   X>320575</National Grid Reference   X><National Grid Reference Y>240640</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\3860-08 Darndale Park, Darndale, Dublin 17</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>225</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaway 4m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="43"><Database Reference>43</Database Reference><Location>18 Kilbride Rd Killester</Location><Land use>1 house</Land use><National Grid Reference   X>319309.445</National Grid Reference   X><National Grid Reference Y>237394.13</National Grid Reference Y><File/Consent Reference>k:\Development Control\Planning Files\2008\4142-08 18 Kilbride Road, Killester, Dublin 5</File/Consent Reference><Status (constructed or otherwise)>Constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>private</Ownership><Maintained by>private</Maintained by><contributing area (both permeable and impermeable) m2>120</contributing area (both permeable and impermeable) m2><Type of Device>permeable paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>permeable paving: 20m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="44"><Database Reference>44</Database Reference><Location>rear 18 ardee rd</Location><Land use>1 house</Land use><National Grid Reference   X>315573.094</National Grid Reference   X><National Grid Reference Y>231967.5</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2008\4900-08 18 Ardee Road</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>private</Ownership><Maintained by>private</Maintained by><contributing area (both permeable and impermeable) m2>104</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank:0.566m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="45"><Database Reference>45</Database Reference><Location>36 grave rd</Location><Land use>18 apartments</Land use><National Grid Reference   X>315107.531</National Grid Reference   X><National Grid Reference Y>232359.092</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\1083-06 36 Grove Road</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>private</Ownership><Maintained by>private</Maintained by><contributing area (both permeable and impermeable) m2>650</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank:.10.31m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="46"><Database Reference>46</Database Reference><Location>Deanstown Green</Location><Land use>Council Apartments</Land use><National Grid Reference   X>312102.5</National Grid Reference   X><National Grid Reference Y>238436.3</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\1922-06 Deanstown Green</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>2520</contributing area (both permeable and impermeable) m2><Type of Device>Permeable Paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving: 255m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="47"><Database Reference>47</Database Reference><Location>Sion Hill Rd</Location><Land use>3 storey apartment block</Land use><National Grid Reference   X>317182.031</National Grid Reference   X><National Grid Reference Y>237549.641</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\1938-06 Apts at Sion Hill Road</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>1023</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation pipe</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation pipe 10.3m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="48"><Database Reference>48</Database Reference><Location>111 Howth rd </Location><Land use>4 house Development</Land use><National Grid Reference   X>318832.125</National Grid Reference   X><National Grid Reference Y>236644.703</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\2443-06 111 Howth Road Lawrence Grove Dublin 3</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>1650</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation Tank: 18m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="49"><Database Reference>49</Database Reference><Location>18 upper drumcondra rd</Location><Land use>New office building</Land use><National Grid Reference   X>316254.5</National Grid Reference   X><National Grid Reference Y>236849</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\2491-06 18 Upper Drumcondra Road</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>110</contributing area (both permeable and impermeable) m2><Type of Device>green roof</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Green roof 25m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="50"><Database Reference>50</Database Reference><Location>43 lucky lane</Location><Land use>Single house</Land use><National Grid Reference   X>313789.25</National Grid Reference   X><National Grid Reference Y>235182.063</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\2644-06 43 Lucky lane, Stonybatter</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>125</contributing area (both permeable and impermeable) m2><Type of Device>permeable paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>permeable paving 18m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="51"><Database Reference>51</Database Reference><Location>84 Briarfield rd, killbarrack Dublin 5</Location><Land use>2 houses</Land use><National Grid Reference   X>322317.2</National Grid Reference   X><National Grid Reference Y>238845.9</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\2753-06 84 Briarfield Road Kilbarrack Dublin 5 Niall Brunswick</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>735</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank 10m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="52"><Database Reference>52</Database Reference><Location>Mellows rd, fingals Dublin 11</Location><Land use>Garda Station</Land use><National Grid Reference   X>312702</National Grid Reference   X><National Grid Reference Y>239027.953</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\2917-06 OPW Mellows Road Finglas Dublin 11</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>3325</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank 100m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="53"><Database Reference>53</Database Reference><Location>Grange park drive</Location><Land use>single house</Land use><National Grid Reference   X>322028.563</National Grid Reference   X><National Grid Reference Y>239034.813</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\3464-06 14 Grange Park Drive, Raheny, Dublin 5</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>196</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaway :2.4m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="54"><Database Reference>54</Database Reference><Location>2a Donaghmede Drive</Location><Land use>single house</Land use><National Grid Reference   X>322631.594</National Grid Reference   X><National Grid Reference Y>239688.813</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\3995-06 2a Donaghmede Drive Raheny, Dublin 13</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>224</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaway :2.4m4</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="55"><Database Reference>55</Database Reference><Location>55 Roseglen Rd</Location><Land use>2 houses</Land use><National Grid Reference   X>322442.592</National Grid Reference   X><National Grid Reference Y>238710.139</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\4287-06 55a &amp; 55b Roseglen Road</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>430</contributing area (both permeable and impermeable) m2><Type of Device>Permeable Paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving: 91.7m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="56"><Database Reference>56</Database Reference><Location>Collin Av Ext</Location><Land use>Single house</Land use><National Grid Reference   X>315726.384</National Grid Reference   X><National Grid Reference Y>238903.593</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\4363-06 Rear 651 Collins Avenue Extension</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>288</contributing area (both permeable and impermeable) m2><Type of Device>Permeable Paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving: 40m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="57"><Database Reference>57</Database Reference><Location>45 oak rd Donnycarney d9</Location><Land use>Single house</Land use><National Grid Reference   X>318379.676</National Grid Reference   X><National Grid Reference Y>237544.501</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\4620-06 45 Oak Road Donnycarney Dublin 9</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>210</contributing area (both permeable and impermeable) m2><Type of Device>Permeable Paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving: 38m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="58"><Database Reference>58</Database Reference><Location>6 kincora Av,</Location><Land use>Single house</Land use><National Grid Reference   X>319286.188</National Grid Reference   X><National Grid Reference Y>236301</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\4749-06 adj 6 Kincora Avenue</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>420</contributing area (both permeable and impermeable) m2><Type of Device>soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaway: N\A</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="59"><Database Reference>59</Database Reference><Location>48 Fleet St</Location><Land use>Commercial/Residential development</Land use><National Grid Reference   X>315885.022</National Grid Reference   X><National Grid Reference Y>234207.849</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\4939-06 48 Fleet Street</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>350</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank: 6m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="60"><Database Reference>60</Database Reference><Location>72 seafield rd</Location><Land use>2 houses</Land use><National Grid Reference   X>320347.281</National Grid Reference   X><National Grid Reference Y>236472.656</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\4985-06 72 Seafield Road, Clontarf</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>572</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank: 1.6m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="61"><Database Reference>61</Database Reference><Location>Shieling hotel Howth</Location><Land use>Redevelopment and extension of hotel</Land use><National Grid Reference   X>322405.469</National Grid Reference   X><National Grid Reference Y>238177.453</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5067-06 Shieling Hotel, Howth road, Raheny, Dublin 5</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>7665</contributing area (both permeable and impermeable) m2><Type of Device>Permeable paving, swale  and attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving:188m2, Attenuation tank:198m3, Swale: 90m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 3.3l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="62"><Database Reference>62</Database Reference><Location>St Vincent's hospital Merion rd</Location><Land use>New Building for hospital</Land use><National Grid Reference   X>319426.553</National Grid Reference   X><National Grid Reference Y>230952.238</National Grid Reference Y><File/Consent Reference>:\Development Control\Planning Files\2006\5120-06 St Vincent's Hospital</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>13560</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank:400m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 5l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="63"><Database Reference>63</Database Reference><Location>23 Barry rd finglas</Location><Land use>apartment block</Land use><National Grid Reference   X>312344.563</National Grid Reference   X><National Grid Reference Y>239534.422</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5281-06 23 Barry Road, Finglas, Dublin 11</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>441</contributing area (both permeable and impermeable) m2><Type of Device>Permeable Paving an soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>permeable paving 30m2, soakaway 12m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="64"><Database Reference>64</Database Reference><Location>Fr Scully house, Gardiner st</Location><Land use>Housing block</Land use><National Grid Reference   X>316024.789</National Grid Reference   X><National Grid Reference Y>235240.243</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5495-06 Fr. Scully House</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>2240</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank:120m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="65"><Database Reference>65</Database Reference><Location>Sean Treacy House,Buckingham St</Location><Land use>Housing block</Land use><National Grid Reference   X>316540.747</National Grid Reference   X><National Grid Reference Y>235361.726</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5496-06 Sean Treacy House, Buckingham Street</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>3584</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank:75m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="66"><Database Reference>66</Database Reference><Location>128 lower kimmage rd, d6</Location><Land use>2 houses</Land use><National Grid Reference   X>314186.271</National Grid Reference   X><National Grid Reference Y>231281.166</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5570-06 128 Lower Kimmage Road, Harold's Cross, Dublin 6</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>528</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank:4.3m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="67"><Database Reference>67</Database Reference><Location>Navan Road Nephen rd</Location><Land use>25 apartments</Land use><National Grid Reference   X>312669.562</National Grid Reference   X><National Grid Reference Y>236236.549</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5631-06 Navan Road Nephin Road</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>1978</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank:43.2m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="68"><Database Reference>68</Database Reference><Location>Sean O Casey Community Centre , Saint Marys Rd ,East Wall</Location><Land use>Community Centre</Land use><National Grid Reference   X>317650.299</National Grid Reference   X><National Grid Reference Y>235067.379</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5633-06 Sean OCasey Community Centre Saint Marys Road East Wall Dublin 3 cora</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>1962</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>3 soakaways:  6m3 ,  37.5m3, , 15m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="69"><Database Reference>69</Database Reference><Location>beech hill drive</Location><Land use>9 new houses</Land use><National Grid Reference   X>317840.313</National Grid Reference   X><National Grid Reference Y>230946.047</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5765-06 Beech Hill Drive Donnybrook</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>1716</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>9 Soakaways 2m3 each</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="70"><Database Reference>70</Database Reference><Location>Asling hotel parkgate st</Location><Land use>Hotel redevelopment</Land use><National Grid Reference   X>313854.939</National Grid Reference   X><National Grid Reference Y>234428.309</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5772-06 Aishling Hotel, Parkgate Street</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>3420</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank: 34m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="71"><Database Reference>71</Database Reference><Location>11 Cleggan Rd</Location><Land use>2 houses</Land use><National Grid Reference   X>309012.7</National Grid Reference   X><National Grid Reference Y>233833.8</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\5957-06 11 Cleggan Road</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>495</contributing area (both permeable and impermeable) m2><Type of Device>permeable paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>permeable paving: 35m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="72"><Database Reference>72</Database Reference><Location>32 Edenmore ave Raheny</Location><Land use>8 apartments</Land use><National Grid Reference   X>320694.844</National Grid Reference   X><National Grid Reference Y>239023.984</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\6462-06 32-34A Edenmore Ave, Raheny</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>561</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank: 7.56m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="73"><Database Reference>73</Database Reference><Location>51 Holywell Cresent</Location><Land use>Single house</Land use><National Grid Reference   X>322218.906</National Grid Reference   X><National Grid Reference Y>239669.266</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\6688-06 51 Holywell Crescent, Donaghmede, D13</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>233</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaway: n/a</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="74"><Database Reference>74</Database Reference><Location>49 castle Grove, Clontarf</Location><Land use>Single house</Land use><National Grid Reference   X>319601.509</National Grid Reference   X><National Grid Reference Y>236845.826</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\6868-06 49 Castle Grove, Clontarf, Dublin 3</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>297</contributing area (both permeable and impermeable) m2><Type of Device>Permeable paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving: 120m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="75"><Database Reference>75</Database Reference><Location>Brookfeild house , westpark, artane</Location><Land use>60 apartment and office</Land use><National Grid Reference   X>320356.084</National Grid Reference   X><National Grid Reference Y>238826.56</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2005\1103-05 Brookville House, Westpark, Artane, D5</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>3000</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank </Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation tank: 50m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="76"><Database Reference>76</Database Reference><Location>Martins Row Chaplizod</Location><Land use>20 apartments</Land use><National Grid Reference   X>309835.188</National Grid Reference   X><National Grid Reference Y>235050</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2005\1780-05 Martins Row Chapelizod O'Connor Sutton Cronin Brian Cronin</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>780</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation pipe</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation pipe : 45m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="77"><Database Reference>77</Database Reference><Location>Ivy Cottages, Howth Junction court</Location><Land use>12 Apartments</Land use><National Grid Reference   X>322621.449</National Grid Reference   X><National Grid Reference Y>239374.996</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2005\4827-05 Howth Junction Court, Dublin 5</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>1512</contributing area (both permeable and impermeable) m2><Type of Device>Attenuation Tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Attenuation Tank:18m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="78"><Database Reference>78</Database Reference><Location>17 Foxes lane</Location><Land use>2 Houses</Land use><National Grid Reference   X>322743.969</National Grid Reference   X><National Grid Reference Y>238161.891</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2005\5463-05 17 a &amp; b Foxes Lane, Raheny, D5</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>483m2</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaway:1.57m2 </Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="79"><Database Reference>79</Database Reference><Location>Merton drive</Location><Land use>6 houses</Land use><National Grid Reference   X>316724</National Grid Reference   X><National Grid Reference Y>231591.5</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2005\6150-05 Merton Drive</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>2400</contributing area (both permeable and impermeable) m2><Type of Device>Permeable paving and attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving :62m2  attenuation tank: 9.1m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="80"><Database Reference>80</Database Reference><Location>1 Newbrook av</Location><Land use>1 house</Land use><National Grid Reference   X>322419.813</National Grid Reference   X><National Grid Reference Y>239824.578</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2005\6234-05 1 Newbrook Ave, Donaghmede, Dublin 13</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>306</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Soakaway: 1.5m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="81"><Database Reference>81</Database Reference><Location>Beaumount  oncology</Location><Land use>new oncology building</Land use><National Grid Reference   X>318411.779</National Grid Reference   X><National Grid Reference Y>239290.559</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2009\2489-09 Beaumont Hospital Oncology Building Phase 1</File/Consent Reference><Status (constructed or otherwise)>construction not started</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>10000</contributing area (both permeable and impermeable) m2><Type of Device>permeable paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>permeable paving 3104m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="82"><Database Reference>82</Database Reference><Location>15a tolka cottages glasneven </Location><Land use>Single house</Land use><National Grid Reference   X>314218.503</National Grid Reference   X><National Grid Reference Y>237921.108</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2009\3311-09 15a Tolka Cottages, Glasnevin, Dublin 11</File/Consent Reference><Status (constructed or otherwise)>construction not started</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>780</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Soakaway:0. 5m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="83"><Database Reference>83</Database Reference><Location>Capuchin Friary, Belmount Park Raheny</Location><Land use>Redevelopment and extension</Land use><National Grid Reference   X>321654.085</National Grid Reference   X><National Grid Reference Y>238739.536</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2009\3561-09 Capuchin Friary, Belmont Park, Raheny, Dublin 5</File/Consent Reference><Status (constructed or otherwise)>construction not started</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>7000</contributing area (both permeable and impermeable) m2><Type of Device>Permeable paving and attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving :200m2, Attenuation tank 94m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="84"><Database Reference>84</Database Reference><Location>25 Monasterboice Rd</Location><Land use>Single house</Land use><National Grid Reference   X>313054.969</National Grid Reference   X><National Grid Reference Y>231798.578</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2009\5879-09 25 Monasterboice Road, Crumlin</File/Consent Reference><Status (constructed or otherwise)>construction not started</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>384</contributing area (both permeable and impermeable) m2><Type of Device>Permeable paving and attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Permeable paving :38m2, Attenuation tank 1.5m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="85"><Database Reference>85</Database Reference><Location>82a Spiddal Rd</Location><Land use>Single house</Land use><National Grid Reference   X>308655.719</National Grid Reference   X><National Grid Reference Y>233520.656</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2005\4549-05 82A Spiddal Road</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>174</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakaway : 10m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="86"><Database Reference>86</Database Reference><Location>6 Burlington rd</Location><Land use>Mixed use Development</Land use><National Grid Reference   X>316934.992</National Grid Reference   X><National Grid Reference Y>232700.225</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\2401-06 Burlington Road Dublin 8</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>7400</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank:200m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="87"><Database Reference>87</Database Reference><Location>Sandford Pk School Ranelagh</Location><Land use>School</Land use><National Grid Reference   X>316659.937</National Grid Reference   X><National Grid Reference Y>231672.277</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\2990-06 Sandford Park School Ranelagh</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>7728</contributing area (both permeable and impermeable) m2><Type of Device>Filter Drain and soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Filter drain 26.8m3, Soakaway: 24m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="88"><Database Reference>88</Database Reference><Location>St Mary Drive</Location><Land use>Single house</Land use><National Grid Reference   X>311954.688</National Grid Reference   X><National Grid Reference Y>231688.5</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\3035-06 St Mary's Drive</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>120</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakway: 2m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="89"><Database Reference>89</Database Reference><Location>219a Clonard Rd</Location><Land use>Single house</Land use><National Grid Reference   X>313221.5</National Grid Reference   X><National Grid Reference Y>231219.3</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2006\3823-06 219A Clonard Road</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>140</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway and permeable paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Soakaway: 2m3 and permeable paving 30m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="90"><Database Reference>90</Database Reference><Location>1a shrewbury park</Location><Land use>Single house</Land use><National Grid Reference   X>318646.563</National Grid Reference   X><National Grid Reference Y>231978.422</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\1875-07 1a Shrewsbury Park</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>320</contributing area (both permeable and impermeable) m2><Type of Device>Soakaway</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>soakway: 2m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="91"><Database Reference>91</Database Reference><Location>whiteheather industrial estate</Location><Land use>construction of new warehouse</Land use><National Grid Reference   X>313991.33</National Grid Reference   X><National Grid Reference Y>232662.531</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\2316-07 Whiteheather Industrial Estate</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>1008</contributing area (both permeable and impermeable) m2><Type of Device>attenuation tank</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>attenuation tank:104m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="92"><Database Reference>92</Database Reference><Location>4-5 protestant row</Location><Land use>5 storey apartment block</Land use><National Grid Reference   X>315630.282</National Grid Reference   X><National Grid Reference Y>233263</National Grid Reference Y><File/Consent Reference>K:\Development Control\Planning Files\2007\3930-07 4-5 Protestant Row</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>Private</Ownership><Maintained by>Private</Maintained by><contributing area (both permeable and impermeable) m2>378</contributing area (both permeable and impermeable) m2><Type of Device>permeable paving</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>permeable paving: 90m2</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="93"><Database Reference>93</Database Reference><Location>Tolka Valley wetland</Location><Land use>N/A</Land use><National Grid Reference   X>313081.069</National Grid Reference   X><National Grid Reference Y>237550</National Grid Reference Y><File/Consent Reference>N/a</File/Consent Reference><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>50000</contributing area (both permeable and impermeable) m2><Type of Device>Wetland</Type of Device><Reason for Installation>Pollution Prevention</Reason for Installation><Physical Features,  (Shape, size, etc)>Wetland 1000m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>n/a</Outflow Flow limit><Ecological Features (Plant life)>See case study 2</Ecological Features (Plant life)><Water Quality>See case study 2</Water Quality></row>
<row _id="94"><Database Reference>94</Database Reference><Location>Glendhu Park</Location><Land use>N/A</Land use><National Grid Reference   X>311698.236</National Grid Reference   X><National Grid Reference Y>237361.672</National Grid Reference Y><File/Consent Reference>N/a</File/Consent Reference><Status (constructed or otherwise)>under construction</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Greenfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>187000</contributing area (both permeable and impermeable) m2><Type of Device>2 No. Swale</Type of Device><Reason for Installation>Flood prevention</Reason for Installation><Physical Features,  (Shape, size, etc)>2 No Swales 2482m3</Physical Features,  (Shape, size, etc)><Outflow Flow limit>n/a</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
<row _id="95"><Database Reference>95</Database Reference><Location>York st </Location><Land use>sixty-six social housing units </Land use><National Grid Reference   X>315688.6</National Grid Reference   X><National Grid Reference Y>233470.1</National Grid Reference Y><File/Consent Reference /><Status (constructed or otherwise)>constructed</Status (constructed or otherwise)><Previous land use (Greenfield or Brownfield)>Brownfield</Previous land use (Greenfield or Brownfield)><Ownership>public</Ownership><Maintained by>public</Maintained by><contributing area (both permeable and impermeable) m2>2130</contributing area (both permeable and impermeable) m2><Type of Device>Greenroof and rainwater harvesting tanks</Type of Device><Reason for Installation>Planning Requirement</Reason for Installation><Physical Features,  (Shape, size, etc)>Greenroof 1200m2 and rainwater harvesting tanks 14*3.6</Physical Features,  (Shape, size, etc)><Outflow Flow limit>Hydrobrake 2l/s</Outflow Flow limit><Ecological Features (Plant life) /><Water Quality /></row>
</data>
