{"help": "https://data.smartdublin.ie/en/api/3/action/help_show?name=datastore_search", "success": true, "result": {"include_total": true, "limit": 100, "records_format": "objects", "resource_id": "64563279-a530-44d6-870c-4102aa2f0852", "total_estimation_threshold": null, "records": [{"_id":1,"Development Name":"Anglesey House (W)","Location":"Blackrock","bldg__ctrl__no_":"BC 1845","Status":"Incomplete","Hyperlink":"Anglesey House BC1845","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":2,"Development Name":"Ardmore Park (E)","Location":"Sallynogin","bldg__ctrl__no_":"BC 1814","Status":"Incomplete","Hyperlink":"Ardmore Park BC1814","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":3,"Development Name":"Barclay Court (W)","Location":"Blackrock","bldg__ctrl__no_":"BC 1854","Status":"Incomplete","Hyperlink":"Barclay Court BC1854","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":4,"Development Name":"Carrickmines Manor (E)","Location":"Carrickmines","bldg__ctrl__no_":"BC 1847","Status":"Complete","Hyperlink":"Carrickmines Manor BC1847","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"No drainage information available","Comments - Additional Files":null},{"_id":5,"Development Name":"Cherrywood Town City (E)","Location":"Cherrywood","bldg__ctrl__no_":"BC 1859","Status":"Incomplete","Hyperlink":"Cherrywood T.C BC1859","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":6,"Development Name":"Clonbur (E)","Location":"Foxrock","bldg__ctrl__no_":"BC 1858","Status":"Incomplete","Hyperlink":"Clonbur Foxrock BC1858","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":7,"Development Name":"Feldberg","Location":"Glenageary","bldg__ctrl__no_":"BC 1846","Status":"Incomplete","Hyperlink":"Feldberg BC1846","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":8,"Development Name":"Flanagan's","Location":"Mount Merrion","bldg__ctrl__no_":"BC 1863","Status":"Major Issue","Hyperlink":"Flanagan's Mount Merrion BC1863","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Empty File Folder","Comments - Additional Files":null},{"_id":9,"Development Name":"Fortwilliam Cottages (E)","Location":"-","bldg__ctrl__no_":"BC 1828","Status":"Incomplete","Hyperlink":"Fortwilliam Cottages BC1828","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":10,"Development Name":"Greythorn Manor (E)","Location":"Glenageary","bldg__ctrl__no_":"BC 1823","Status":"Incomplete","Hyperlink":"Greythorn Manor BC1823","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":11,"Development Name":"Hazelbrook Sq. The Court","Location":"Rathfarnham","bldg__ctrl__no_":"BC 1861","Status":"Incomplete","Hyperlink":"Hazelbrook Sq. The Court BC1861","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":12,"Development Name":"Kilmacud House (E)","Location":"Stillorgan","bldg__ctrl__no_":"BC 1848","Status":"Incomplete","Hyperlink":"Kilmacud House BC1848","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":13,"Development Name":"Library Road (E)","Location":"Shankill","bldg__ctrl__no_":"BC 1830","Status":"Incomplete","Hyperlink":"Library Rd. Shankill BC1830","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no surface water drainage shown on drawing","Comments - Additional Files":null},{"_id":14,"Development Name":"Quarry Rd (E)","Location":"Rathmichael","bldg__ctrl__no_":"BC 1834","Status":"Incomplete","Hyperlink":"Quarry Rd BC1834","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":15,"Development Name":"Rosemount Cottage (W)","Location":"Dundrum","bldg__ctrl__no_":"BC 1853","Status":"Incomplete","Hyperlink":"Rosemount Cottage BC1853","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":16,"Development Name":"Stillorgan Park (E)","Location":"Stillorgan","bldg__ctrl__no_":"BC 1855","Status":"Incomplete","Hyperlink":"Stillorgan Park BC1855","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File no drainage drawing","Comments - Additional Files":null},{"_id":17,"Development Name":"Trimbleston Phase 2 (W)","Location":"-","bldg__ctrl__no_":"-","Status":"Major Issue","Hyperlink":"-","Consultant Engineers":"-","suds_built__y_n_":"-","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Empty File Folder","Comments - Additional Files":null},{"_id":18,"Development Name":"Adelaide Rd (E)","Location":"Dun Laoghaire","bldg__ctrl__no_":"BC 1840","Status":"Complete","Hyperlink":"Adelaide Rd BC1840","Consultant Engineers":"DBFL","suds_built__y_n_":"No","h_brake_1__y___n_":"`-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"No attenuation details","Comments - Additional Files":null},{"_id":19,"Development Name":"Belmont Sector 2 (W)","Location":"Sandyford","bldg__ctrl__no_":"BC 1738.2","Status":"Complete","Hyperlink":"Belmont-Sector 2 BC1738.2","Consultant Engineers":"DBFL","suds_built__y_n_":"No","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Apparently no attenuation present. FW and SW shown on drawing 133082 but not directly associated with Belmont Development","Comments - Additional Files":null},{"_id":20,"Development Name":"Brookside (E)","Location":"Blackrock","bldg__ctrl__no_":"BC 1851","Status":"Complete","Hyperlink":"Brookside BC1851","Consultant Engineers":"Virtus Construction Consultants","suds_built__y_n_":"No","h_brake_1__y___n_":"No","Hydrobrake Details":"-","SUDS Type 1":"Soakaway","SUDS Measure Description 1":"Multiple Cultec Soakaways, one soakaway per house","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":21,"Development Name":"Carrrickmines Green (E)","Location":"Carrickmines","bldg__ctrl__no_":"BC 1588","Status":"Complete","Hyperlink":"Carrickmines Green BC1588","Consultant Engineers":"Waterman Moylans","suds_built__y_n_":"No","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":22,"Development Name":"Clonlost House (E)","Location":"Dalkey","bldg__ctrl__no_":"BC 1788","Status":"Complete","Hyperlink":"Clonlost House BC1788","Consultant Engineers":"ONCE Civil & Structural","suds_built__y_n_":"No","h_brake_1__y___n_":"Yes","Hydrobrake Details":"No details","SUDS Type 1":"Oversized Pipe","SUDS Measure Description 1":"900mm Dia Oversized pipe","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":23,"Development Name":"Clon Brugh","Location":"Aikens Village","bldg__ctrl__no_":"BC1485A","Status":"TIC Files - Incomplete","Hyperlink":"Clon Brugh BC1485A","Consultant Engineers":"-","suds_built__y_n_":"No","h_brake_1__y___n_":"No","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":24,"Development Name":"Greygates (W)","Location":"Mount Merrion","bldg__ctrl__no_":"BC 1820","Status":"Complete","Hyperlink":"Greygates BC1820","Consultant Engineers":"Duffy Chartered Engineers","suds_built__y_n_":"No","h_brake_1__y___n_":"No","Hydrobrake Details":"-","SUDS Type 1":"Enlarged Pipe","SUDS Measure Description 1":"600mm diameter pipe providing approximately 23m3 attenuation","SUDS Type 2":"Rainwater Harvesting Tank","SUDS Measure Description 2":"8000 litre rainwater harvesting tank","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"600mm diameter pipe used as attenuation, pipe is very close to building foundations. There is a wayleave but it is extend to one side only.","Comments - Additional Files":null},{"_id":25,"Development Name":"Kenlar (W)","Location":"Sandyford","bldg__ctrl__no_":"BC 1815","Status":"Complete","Hyperlink":"Kenler BC1815","Consultant Engineers":"Pat O'Gorman & Associates","suds_built__y_n_":"No","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Rainwater Butts and Soakaways present","Comments - Additional Files":null},{"_id":26,"Development Name":"Royal Marine Hotel","Location":"Dun Laoghaire","bldg__ctrl__no_":"BC 1789","Status":"Complete","Hyperlink":"Royal Marine Hotel BC 1789","Consultant Engineers":"Muir Assoicates Ltd","suds_built__y_n_":"No","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":27,"Development Name":"Springhill House (E)","Location":"Killiney","bldg__ctrl__no_":"BC 1798","Status":"Incomplete","Hyperlink":"Springhill House BC1798","Consultant Engineers":"Killiney Design Associates","suds_built__y_n_":"No","h_brake_1__y___n_":"No","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"No Attenuation","Comments - Additional Files":null},{"_id":28,"Development Name":"214 Rochestown Ave (E)\r - Auburn Green","Location":"Glenageary","bldg__ctrl__no_":"BC 1841","Status":"Complete","Hyperlink":"214 Rochestown Ave. BC1841","Consultant Engineers":"Barrett Mahony Con. Eng","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake, Discharge Limited to 3.3 l/s, minimum size of hydrobrake opening to be 75mm","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Stormtech SC-740, 66m3. IL 45.782 / TOW 46.850","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":"Existing Foul and Surface Water have been diverted to proposed FW and SW systems.\r Onsite company director Matthew Lyster (0866676768)"},{"_id":29,"Development Name":"Aiken Village,Dun Gaoithe (W)","Location":"Dun Laoghaire","bldg__ctrl__no_":"BC 1842","Status":"Complete","Hyperlink":"Aiken Village,Dun Gaoithe BC1842","Consultant Engineers":"CS Consulting Group","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake, Discharge Limited to 4.1 l/s, \r CL 121.60, IL 116.222","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Stormtech, 335m3","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Minimal Details on attenuation details","Comments - Additional Files":null},{"_id":30,"Development Name":"Ard na Geine (W)","Location":"Churchtown","bldg__ctrl__no_":"BC 1831","Status":"TIC Files - Complete","Hyperlink":"Ard na Geine BC1831","Consultant Engineers":"Kavanagh Burke Con.Engs","suds_built__y_n_":"Yes","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"Soakaway","SUDS Measure Description 1":"Soakaway Stormtech x 2, No volume shown on the drawing","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Drainage drawing found in TIC files","Comments - Additional Files":"-"},{"_id":31,"Development Name":"Ardilea Cresent (W)","Location":"Clonskeagh","bldg__ctrl__no_":"BC1776","Status":"TIC Files - Complete","Hyperlink":"Ardilea Crescent BC1776","Consultant Engineers":"DBFL","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Not on dwg. Prob. S4A","Hydrobrake Details":"-","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Attenuation tank to store run off for 1 in 100 year storm. TWL=51.10m AOD, IL=49.60m, GL=52.00m.\r Dimensions=160m2 x 1.5m Deep, Volume=240m3, Dividing Weir Level=50.80m","SUDS Type 2":"Green Roof on apartment blocks","SUDS Measure Description 2":"No details","Additional SUDS":"-","Additional SUDS Description":"-","Comments":null,"Comments - Additional Files":"Multiple issues with SW pipes, these include water infiltration, connections not sealed and joint gaps. Developer was O'Malley Construction"},{"_id":32,"Development Name":"Balure (E)","Location":"Glenageary","bldg__ctrl__no_":"BC1774","Status":"Complete","Hyperlink":"Balure BC1774","Consultant Engineers":"GNCE","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Flow restricted to 2.0l/s (S4)","SUDS Type 1":"Stormtech","SUDS Measure Description 1":"\"Designed for a 100yr event with a storage required of 115.0m3. IL 48.94m3\"","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":33,"Development Name":"Beech Park","Location":"Cabinteely","bldg__ctrl__no_":"BC 1864","Status":null,"Hyperlink":"Beechpark Cabinteely BC1864","Consultant Engineers":"Muir Associates","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Y","Hydrobrake Details":"Hydrobrake, Discharge Limited to 9.6l/s / Hydrobrake, Discharge Limited to 1.0l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"\"Proposed Underground 95% Void Ratio Modular Storage\"","SUDS Type 2":"Temporary pond","SUDS Measure Description 2":"Temporary surface water treatment and attenuation, discharge limited to 9.0 l/s","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"All SUDS measures to be place under road?","Comments - Additional Files":"Latest drawing is for enabling works and does not show the drainage plans for the apartment block to the East of the site."},{"_id":34,"Development Name":"Belarmine Ph.3 (W)","Location":"Stepaside","bldg__ctrl__no_":"BC 1849","Status":"Complete","Hyperlink":"Belarmine Ph.3 BC1849","Consultant Engineers":"Waterman Moylans","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake, Discharge Limited to 1.6l/s\r Hydrobrake, Discharge Limited to 3.6l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Stormtec, Volume  241m3","SUDS Type 2":"Attenuation Tank","SUDS Measure Description 2":"Underground Storage, 278m3, TWL 110.5m","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":35,"Development Name":"Belmont Sector 1 (W)","Location":"Sandyford","bldg__ctrl__no_":"BC 1738","Status":"Complete","Hyperlink":"Belmont,Sector 1, Aikens Village BC1738","Consultant Engineers":"DBFL","suds_built__y_n_":"Yes","h_brake_1__y___n_":"No","Hydrobrake Details":"-","SUDS Type 1":"Swale","SUDS Measure Description 1":"\"Details to be agreed with DLRCC\"","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":36,"Development Name":"Bishops Gate (Phase 1) (E)","Location":"Kilternan","bldg__ctrl__no_":"BC1810","Status":"Complete","Hyperlink":"Bishops Gate BC1810","Consultant Engineers":"Rodger Mullarkey & Associates","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"\"Limiting flow to 25l/s, il=126.40.\r Provide a high level inlet/outlet 525 dia at il=128.00\"","SUDS Type 1":"GEO Light Storage Tank","SUDS Measure Description 1":"Off-line Underground Stormcell Tank","SUDS Type 2":"Detention Basin","SUDS Measure Description 2":"Bed Level 127.75m OD","Additional SUDS":null,"Additional SUDS Description":null,"Comments":"Existing spring to be diverted via 300 dia. 375mm x 450mm Culvert being diverted.","Comments - Additional Files":null},{"_id":37,"Development Name":"Bishops Gate (Phase 2) (E)","Location":"Kilternan","bldg__ctrl__no_":"BC1810","Status":"Complete","Hyperlink":"Bishops Gate BC1810","Consultant Engineers":"Rodger Mullarkey & Associates","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"-","SUDS Type 1":"Cellular Storage System","SUDS Measure Description 1":"200m3 Total","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":38,"Development Name":"Brehon Chair (W)","Location":"Rathfarnham","bldg__ctrl__no_":"BC 1850","Status":"Complete","Hyperlink":"Brehon Chair BC1850","Consultant Engineers":"Corrigan Hodnett Consulting","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake, Discharge Limited to 1.2 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"MC3500 Stormtech Attenuation Tank","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":null,"Comments - Additional Files":null},{"_id":39,"Development Name":"Brighton Wood (W)","Location":"Leopardstown","bldg__ctrl__no_":"BC1804","Status":"Incomplete","Hyperlink":"Brighton Wood BC1804","Consultant Engineers":"Waterman Moylans","suds_built__y_n_":"Yes","h_brake_1__y___n_":null,"Hydrobrake Details":"-","SUDS Type 1":"Multiple Swales","SUDS Measure Description 1":"Multiple Swales adjacent to roadways","SUDS Type 2":"Pond to store M30 event/M30 to M100 storage in woodland area","SUDS Measure Description 2":"-","Additional SUDS":null,"Additional SUDS Description":null,"Comments":"Dry ditch present, proprosal for ditch to drain into swale. Foul storage tank, not sure if it is being used.","Comments - Additional Files":null},{"_id":40,"Development Name":"Broadlands (E)","Location":"Glenageary","bldg__ctrl__no_":"BC 1801","Status":"Complete","Hyperlink":"Broadlands BC1801","Consultant Engineers":"Donnachadh O'Brien & Associates","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes\r Att. Tank 1","Hydrobrake Details":"SW manhole with HRD, SHE-0090-3000-0500-3000 Flow control limited to 3.0 l/s, CL 59.37 /IL 57.70, (100mm Overflow IL 58.95)\r SW manhole with HRD, SHE-0090-3700-1100-3700 Flow control limited to 3.7 l/s, IL 58.35, (100mm Overflow IL 59.60)","SUDS Type 1":"Pluvial Cube Attenuation Tank 1","SUDS Measure Description 1":"109m3 Storage\r IL 57.85m","SUDS Type 2":"Pluvial Cube Attenuation Tank 2","SUDS Measure Description 2":"40m3 Storage\r IL 58.50m","Additional SUDS":"Pluvial Cube Attenuation Tank 3","Additional SUDS Description":"75m3 Storage\r IL 58.50m","Comments":"-","Comments - Additional Files":null},{"_id":41,"Development Name":"Camberley Mews (W)","Location":"Churchtown","bldg__ctrl__no_":"BC 1808","Status":"Complete","Hyperlink":"Camberley Mews BC1808","Consultant Engineers":"Barrett Mahony Con. Eng.","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake, Discharge Limited to 2.0 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Existing attenuation tank, unsized","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":null,"Comments - Additional Files":null},{"_id":42,"Development Name":"Carraig Bui (E)","Location":"Cabinteely","bldg__ctrl__no_":"BC 1852","Status":"Complete","Hyperlink":"Carraig Bui BC1852","Consultant Engineers":"Lohan & Donnelly","suds_built__y_n_":"Yes","h_brake_1__y___n_":"No","Hydrobrake Details":"\"Outfall MH, Flow Control Device at 8.77 l/s & penstock\"","SUDS Type 1":"Stormtech SC-740","SUDS Measure Description 1":"\"Attenuation Tank, min. volume 183m3\"\r Further details on drawing","SUDS Type 2":"Green Roof on apartment block","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Duplicate building control number with Glenageary Avenue","Comments - Additional Files":null},{"_id":43,"Development Name":"Castlecourt (W)","Location":"Churchtown","bldg__ctrl__no_":"BC 1817","Status":"Additional Files - Complete","Hyperlink":"Castlecourt, Churchtown BC1817","Consultant Engineers":"Donnacadh O'Brien Con. Engs","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake Manhole Outflow Limited to 2 l/s","SUDS Type 1":"Attenuation Tanks","SUDS Measure Description 1":"No details for size","SUDS Type 2":"Yes","SUDS Measure Description 2":"95% void formed soakaway to serve individual houses in each garden, storage provided 9.5m3","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Partial File, no drainage drawings, survey notes have completed some details. Development has been named Castle Park","Comments - Additional Files":null},{"_id":44,"Development Name":"Clay Farm Phase 1 (W)","Location":"Ballyogan","bldg__ctrl__no_":"BC 1727","Status":"Complete","Hyperlink":"Clay Farm BC1727","Consultant Engineers":"DBFL","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Multiple","Hydrobrake Details":"Flow control device for catchment A 16.3 l/s. IL 94.52.\r Flow control device for catchment B 22.9 l/s. IL 94.52\r Flow control device for catchment C 43.1 l/s. IL 92.72\r Flow control device for catchment D 55.9 l/s.","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Surface water storage catchment A: Stormtech SC 740, Volume 108.2m3 (1:100 Year). IL 94.32m,TWL 95.375\r Surface water storage catchment B: Stormtech SC 740, Volume 307.3m3 (1:100 Year). IL 93.24m,TWL 94.27","SUDS Type 2":"Attenuation Tank","SUDS Measure Description 2":"Surface water storage catchment C: Stormtech SC 740, Volume 290.1m3 (1:100 Year). IL 92.18m, TWL 93.397\r Surface water storage catchment D: Stormtech SC 740, Volume 506.8m3 (1:100 Year). IL 90.97m, TWL 92.39","Additional SUDS":"Swales\r Bioretention Areas","Additional SUDS Description":"Multiple Swales\r Multiple Retention Areas","Comments":"Additional details on drawings","Comments - Additional Files":"Some issues with wayleaves and taken in charge drawings."},{"_id":45,"Development Name":"Clay Farm Phase 2 (W)","Location":"Ballyogan","bldg__ctrl__no_":"BC 1727","Status":"Complete","Hyperlink":"Clay Farm BC1727","Consultant Engineers":"DBFL","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Multiple","Hydrobrake Details":"Flow control device for catchment A 16.3 l/s, Flow control device for catchment B 8.6 l/s,\r Flow control device for catchment C 39.5 l/s, Flow control device for catchment D 13.6 l/s,\r Flow control device for catchment E 28.8 l/s, Flow control device for catchment F 23.5 l/s,\r Flow control device for catchment G 18.3 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Surface water storage catchment A: Stormtech SC 780, Volume 689m3 (1:100 Year). IL 98.50m\r Surface water storage catchment B: Stormtech MC3500, Volume 1105m3 (1:100 Year). IL 101.81m, TWL 103.52\r Surface water storage catchment C: Stormtech MC3500, Volume 506m3 (1:100 Year). IL 95.30m, TWL 96.52","SUDS Type 2":"Attenuation Tank","SUDS Measure Description 2":"Surface water storage catchment D: Stormtech MC3500, Volume 1256m3 (1:100 Year). IL 103.00m\r Surface water storage catchment E: Stormtech MC3500, Volume 568m3 (1:100 Year). IL 92.80m, TWL 94.27\r Surface water storage catchment F: Stormtech MC3500, Volume 366m3 (1:100 Year). IL 95.90m, TWL 97.34\r Surface water storage catchment G: Stormtech MC3500, Volume 1131m3 (1:100 Year). IL 101.3m, TWL 102.58","Additional SUDS":"Swales\r Bioretention Areas","Additional SUDS Description":"Multiple Swales\r Multiple Retention Areas","Comments":"Additional details on drawings","Comments - Additional Files":null},{"_id":46,"Development Name":"Clonkeen Road (E)","Location":"Blackrock","bldg__ctrl__no_":"BC 1793","Status":"Complete","Hyperlink":"Clonkeen Road BC1793","Consultant Engineers":"O'Connor Sutton Cronin","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Q Max 0.6 l/s, Oriface=25mm","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Concrete Storage Tank, 16m x 10m x 1m, 199m3 Storage, CL=39.265, TWL=38.465, IL=37.265","SUDS Type 2":"Interception Storage","SUDS Measure Description 2":"ESS Pluvial Cube, Storage 31.81m3, 5.5m x 6.0m x 1.075m","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":47,"Development Name":"Cluain Shee","Location":"Aikens Village","bldg__ctrl__no_":"BC1485B","Status":"TIC Files - Complete","Hyperlink":"Cluain Shee BC1485B","Consultant Engineers":"Terry & O'Flanagan","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"S0 Hydrobrake, Cl 113.27, IL109.29","SUDS Type 1":"Attenuation Area","SUDS Measure Description 1":"Attenuation Area Storage Capacity = Circa 1100m. Cu","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Details taken from TIC drawings dated September 2007, D121-1002","Comments - Additional Files":null},{"_id":48,"Development Name":"Cualanor (E)","Location":"Aikens Village","bldg__ctrl__no_":"BC 1779","Status":"Complete","Hyperlink":"Cualanor BC1779","Consultant Engineers":"Waterman Moylans","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Y","Hydrobrake Details":"Hydrobrake IL 27.60/CL 32.00. Allowable Discharge 19.8 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"\"Online Surface Water Attenuation Tank (CL 31.50) 1610m x 2.00 max water Level providing 3220m3 of storage\"","SUDS Type 2":"Detention Basin","SUDS Measure Description 2":"Attenuation tank overflows to detention basin.","Additional SUDS":"2 X bio-retention areas at bowling club","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":49,"Development Name":"Dunedin (E)","Location":"Monkstown","bldg__ctrl__no_":"BC 1833","Status":"Complete","Hyperlink":"Dunedin BC1833","Consultant Engineers":"D.C. Turley and Associates","suds_built__y_n_":"Yes","h_brake_1__y___n_":"No","Hydrobrake Details":"Outfall manhole with oriface plate 33dia max, discharge limited to 2 l/s","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"No attenuation","Comments - Additional Files":null},{"_id":50,"Development Name":"Eaton Brae House (E)","Location":"Windy Arbour","bldg__ctrl__no_":"BC 1856","Status":"Complete","Hyperlink":"Eaton Brae House BC1856","Consultant Engineers":"Dean Turner Associates","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Y","Hydrobrake Details":"Penstock valve and flow control device @ 4l/s with min. 75mm morifice and bypass door","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"\"Surface Water Attenuation System\r Wavin Aquacell Size 37.5M Long X 4m\r Wide X 0.8m Deep. (Volume 120m)\"","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"No connection shown from attenuation tank to pipe work","Comments - Additional Files":null},{"_id":51,"Development Name":"Ely Place","Location":"Rathfarnham","bldg__ctrl__no_":"BC 1712","Status":"Complete","Hyperlink":"Ely Place BC1712","Consultant Engineers":"Burroughs","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"\"Manhole S1/4 to house orifice control perforated riser for 1/1, 1/30 & 1/100 storm flows.","SUDS Type 1":"Under-ground storage tank","SUDS Measure Description 1":"150m3 of Q100 storm storage to be provided in underground storage tank. CL 49.92/IL 48.35","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":52,"Development Name":"Enderly","Location":"Dalkey","bldg__ctrl__no_":"BC 1782","Status":"Complete","Hyperlink":"Enderly, Dalkey BC1782","Consultant Engineers":"-","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"\"SW MH No. SW6 to incorporate flow control device - hydrobrake or similar approved to restrict flow to 4.6 l/s sec max.\"","SUDS Type 1":"Stormtech","SUDS Measure Description 1":"\"Stormtech Surface Water Attenuation tank chamber system Ref. MC-3500 (or similar)\r with 300mm of CL505 stone (min. 43% voids) above and below chambers\"","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Discharges to combined sewer? Duplicate BC number with The Cottages, Tivoli Road","Comments - Additional Files":null},{"_id":53,"Development Name":"Fernbank House (W)","Location":"Churchtown","bldg__ctrl__no_":"BC 1816","Status":"Complete","Hyperlink":"Fernbank House BC1816","Consultant Engineers":"DBFL","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake, Discharge Limited to 3.2 l/s\r Hydrobrake, Discharge Limited to 2.1 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Stormbloc, Volume 718m3, IL 45.82m, TWL 47.80m","SUDS Type 2":"Attenuation Tank","SUDS Measure Description 2":"Stormbloc, Volume 148m3, IL 45.56m, TWL 46.22m","Additional SUDS":"Green Roof\r Swale","Additional SUDS Description":"Multiple green roof, Area not provided\r Dry Swale 58m x 2m x 0.5m","Comments":"-","Comments - Additional Files":null},{"_id":54,"Development Name":"Glenart Avenue","Location":"Blackrock","bldg__ctrl__no_":"BC 1821","Status":"Complete","Hyperlink":"Glenart Avenue BC1821","Consultant Engineers":"Cronin & Sutton Consulting","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Oriface Plate Flow Restricter to Limit Outflow to 2l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Attenuation Tank per property x 4","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":55,"Development Name":"Glensavage","Location":"Blackrock","bldg__ctrl__no_":"BC 1860","Status":"Complete","Hyperlink":"Glensavage Blackrock BC1860","Consultant Engineers":"CS Consulting Group","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Flow Control Manhole, discharge limited to 3.4 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Pre-cast attenuation tank, 180m3, 0.9m Deep","SUDS Type 2":"Storage Basin","SUDS Measure Description 2":"Basin with 1:2 side slopes to cater for emergency storm storage","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":56,"Development Name":"Grange Hill (W)","Location":"Ballinteer","bldg__ctrl__no_":"BC 1759","Status":"Complete","Hyperlink":"Grange Hill BC1759","Consultant Engineers":"AKM Consultants","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake IL 115.80/CL 118.10","SUDS Type 1":"Concrete Attenuation Tank","SUDS Measure Description 1":"150m3","SUDS Type 2":"Detention Basin","SUDS Measure Description 2":"IL 117.80","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":57,"Development Name":"Hawthorn (W)","Location":"Clonskeagh","bldg__ctrl__no_":"BC 1803","Status":"Complete","Hyperlink":"Hawthorn BC1803","Consultant Engineers":"Downes Associates","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Flow Control Manhole restricted to 8.29 l/s","SUDS Type 1":"Stormtech SC-790 (740?)","SUDS Measure Description 1":"STORMTECH SC-790 ATTENUATION STORAGE UNITS OR SIMILAR APPROVED\r I.L = 30.515, Volume = 346m2","SUDS Type 2":"Detention Basin","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Seems to be a combination of detention basin and Stormtech SC-740","Comments - Additional Files":null},{"_id":58,"Development Name":"Inglenook (E)","Location":"Carrickmines","bldg__ctrl__no_":"BC 1826","Status":"Complete","Hyperlink":"Inglenook BC1826","Consultant Engineers":"D. Fallon Consulting Engineers","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Discharge Limited to 3.3 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Stormtech SC-740, 177m3","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":59,"Development Name":"Knockrabro (W)","Location":"Goatstown","bldg__ctrl__no_":"BC 1792","Status":"Complete","Hyperlink":"Knocknabro BC1792","Consultant Engineers":"DBFL","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake Optimum Flow Device Manhole 13 l/s @1.6m","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Stormtech mc3500, 9 Rows x 7 Chambers, Volume 344m3, IL 59.263","SUDS Type 2":"Swale","SUDS Measure Description 2":"Bio-retention swale 60m x 5m x 0.5m deep, 61m3","Additional SUDS":"Green Roof\r Bioretention Areas","Additional SUDS Description":"4 x Green Roof, Approx 877m2\r Multiple Retention Areas","Comments":"-","Comments - Additional Files":null},{"_id":60,"Development Name":"Northumberland Close (E)","Location":"Dun Laoghaire","bldg__ctrl__no_":"BC 1838","Status":"Incomplete","Hyperlink":"Northumberland Close BC1838","Consultant Engineers":"Corrigan Hodnett Consulting","suds_built__y_n_":"Yes","h_brake_1__y___n_":"-","Hydrobrake Details":"-","SUDS Type 1":"-","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Some SUDS measures on drawing. No details identified","Comments - Additional Files":null},{"_id":61,"Development Name":"Rockville House (W)","Location":"Glenamuck","bldg__ctrl__no_":"BC 1843","Status":"Complete","Hyperlink":"Rockville House BC1843","Consultant Engineers":"Atkins","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Vortex Flow Control Device to limit discharge rate 4.4 l/s during 1 in 100 year event","SUDS Type 1":"Swale","SUDS Measure Description 1":"-","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"No details for the swale (volume, size)","Comments - Additional Files":null},{"_id":62,"Development Name":"Shandon Park (E)","Location":"Monkstown","bldg__ctrl__no_":"BC 1844","Status":"Complete","Hyperlink":"Shandon Park BC1844","Consultant Engineers":"Killiney Design Associates","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Y","Hydrobrake Details":"Flow control manhole.\r Discharge to be 2.0 l/s/hectare","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Aquacell Attenuation Tank (5.0m x 3.0m x 1.0m)","SUDS Type 2":"Attenuation Tank","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"No details on second attenuation tank","Comments - Additional Files":null},{"_id":63,"Development Name":"Sliverton (W)","Location":"Rathfarnham","bldg__ctrl__no_":"BC 1781","Status":"Complete","Hyperlink":"Sliverton BC1781","Consultant Engineers":"O'Connor Sutton Cronin","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Y","Hydrobrake Details":"1200mm, CL 114.511m, Hydrobrake MH Limited to 2.7 l/s, 450mm(d) Catchpit & Backdrop facility\r S14, 1200mm, CL 112.300m, Hydrobrake MH, Limited to 3.2l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"STORAGE TANK #1, Stormtech SC 740 Series\r Total Attenuation Storage Provided - 57.07m3\r with 200mm layer of OCCR above tank.","SUDS Type 2":"Attenuation Tank","SUDS Measure Description 2":"STORAGE TANK #2\r Stormtech SC 740 Series\r Total Attenuation Storage Provided - 70.70m3\r with 200mm layer of OCCR above tank.","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Additonal details on drawing number N210-H01","Comments - Additional Files":null},{"_id":64,"Development Name":"St Paul's Adelaides Rd (E)","Location":"Glenageary","bldg__ctrl__no_":"BC 1829","Status":"Incomplete","Hyperlink":"St Paul's Adelaides Rd. BC1829","Consultant Engineers":"Kavanagh Burke Con. Engs","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake, Discharge Limited to 2.0 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Details for attenuation systems are off the page.","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"No attenuation details","Comments - Additional Files":null},{"_id":65,"Development Name":"Stanford Park (E)","Location":"Foxrock","bldg__ctrl__no_":"BC 1818","Status":"Complete","Hyperlink":"Stanford Park BC1818","Consultant Engineers":"Conor Furey & Associates Ltd","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"\"SW 1.6, Hydrobrake MH.\r CL 73.33m, IL 70.528m","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Stormtech MC4500, 184m3 Storage Provided. CL 73.28m, TWL 72.67m (>500MM below lowest FFL).\r IL 71.146, OL 71.146","SUDS Type 2":"Attenuation Tank","SUDS Measure Description 2":"Stormtech MC4500, 52m3 Storage Provided. CL 72.09m, TWL 71.12m (>500mm below dwelling FFL). IL 71.12","Additional SUDS":"Infiltration Swale","Additional SUDS Description":"Side Slope 1:3\r 2.9m(W) top, 0.5m (W) bot 13m (L) x 0.4m (DP)","Comments":null,"Comments - Additional Files":null},{"_id":66,"Development Name":"Stepaside Park (Phase 2) (E)","Location":"Stepaside","bldg__ctrl__no_":"BC 1379.1","Status":"Complete","Hyperlink":"Stepaside Park BC1379.1","Consultant Engineers":"DBFL","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Flow Control Manhole restricted to 52 l/s. Design Head 2.46m","SUDS Type 1":"Swale 1","SUDS Measure Description 1":"-","SUDS Type 2":"Detention Basin","SUDS Measure Description 2":"100 yr Flood\r Volume 600m3","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Filter sewer","Comments - Additional Files":null},{"_id":67,"Development Name":"Taney Nurseries (W)","Location":"Dundrum","bldg__ctrl__no_":"BC 1825","Status":"Complete","Hyperlink":"Taney Nurseries BC1825","Consultant Engineers":"Mc Kenna Pearce Practice","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake, Discharge Limited to 4.73 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Aquacell Attenuation Tank (20.0m x 4.5m x 1.2m). Volume 102m3","SUDS Type 2":"Soakaway","SUDS Measure Description 2":"7 x Aquacell Soakaway, 12m x 1.5m x 0.8m, 1 x Aquacell Soakaway, 14m x 1.5m x 0.8m","Additional SUDS":"-","Additional SUDS Description":"-","Comments":null,"Comments - Additional Files":null},{"_id":68,"Development Name":"The Grove (W)","Location":"Goatstown","bldg__ctrl__no_":"BC 1764","Status":"Complete","Hyperlink":"The Grove BC1764","Consultant Engineers":"DBFL","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Flow Control Manhole Limiting Outflow to 5 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Attenuation storage using stormtech sc 740 units.\r Total volume provided = 160m3, IL 38.70m","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":69,"Development Name":"The Rise (W)","Location":"Mount Merrion","bldg__ctrl__no_":"BC 1839","Status":"Complete","Hyperlink":"The Rise BC1839","Consultant Engineers":"Laurence Buckley Con. Eng","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake, Discharge Limited to 2.0 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"JFC Hydro Chamber or Similar Approved","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"Very little information on SUDS measures","Comments - Additional Files":null},{"_id":70,"Development Name":"Westminster Wood (E)","Location":"Foxrock","bldg__ctrl__no_":"BC 1837","Status":"Complete","Hyperlink":"Westminster Wood BC1837","Consultant Engineers":"J.B. Barrys C. Engs","suds_built__y_n_":"Yes","h_brake_1__y___n_":"Yes","Hydrobrake Details":"Hydrobrake, Discharge Limited to 2.0 l/s","SUDS Type 1":"Attenuation Tank","SUDS Measure Description 1":"Pluvial Cube, Volume 230m3","SUDS Type 2":"-","SUDS Measure Description 2":"-","Additional SUDS":"-","Additional SUDS Description":"-","Comments":"-","Comments - Additional Files":null},{"_id":71,"Development Name":"Ashwood Farm (Not Constructed)","Location":null,"bldg__ctrl__no_":null,"Status":null,"Hyperlink":null,"Consultant Engineers":null,"suds_built__y_n_":null,"h_brake_1__y___n_":null,"Hydrobrake Details":null,"SUDS Type 1":null,"SUDS Measure Description 1":null,"SUDS Type 2":null,"SUDS Measure Description 2":null,"Additional SUDS":null,"Additional SUDS Description":null,"Comments":null,"Comments - Additional Files":null},{"_id":72,"Development Name":"Kenmay","Location":null,"bldg__ctrl__no_":null,"Status":"Incomplete","Hyperlink":null,"Consultant Engineers":null,"suds_built__y_n_":null,"h_brake_1__y___n_":null,"Hydrobrake Details":null,"SUDS Type 1":null,"SUDS Measure Description 1":null,"SUDS Type 2":null,"SUDS Measure Description 2":null,"Additional SUDS":null,"Additional SUDS Description":null,"Comments":null,"Comments - Additional Files":null},{"_id":73,"Development Name":"Priory Drive","Location":null,"bldg__ctrl__no_":null,"Status":"Incomplete","Hyperlink":null,"Consultant Engineers":null,"suds_built__y_n_":null,"h_brake_1__y___n_":null,"Hydrobrake Details":null,"SUDS Type 1":null,"SUDS Measure Description 1":null,"SUDS Type 2":null,"SUDS Measure Description 2":null,"Additional SUDS":null,"Additional SUDS Description":null,"Comments":"Mislabelled?","Comments - Additional Files":null}], "fields": [{"id": "_id", "type": "int"}, {"id": "Development Name", "type": "text", "info": {"label": "Development Name"}}, {"id": "Location", "type": "text", "info": {"label": "Location"}}, {"id": "bldg__ctrl__no_", "type": "text", "info": {"label": "Bldg. Ctrl. No."}}, {"id": "Status", "type": "text", "info": {"label": "Status"}}, {"id": "Hyperlink", "type": "text", "info": {"label": "Hyperlink"}}, {"id": "Consultant Engineers", "type": "text", "info": {"label": "Consultant Engineers"}}, {"id": "suds_built__y_n_", "type": "text", "info": {"label": "SUDS Built (Y/N)"}}, {"id": "h_brake_1__y___n_", "type": "text", "info": {"label": "H.brake 1 (Y / N)"}}, {"id": "Hydrobrake Details", "type": "text", "info": {"label": "Hydrobrake Details"}}, {"id": "SUDS Type 1", "type": "text", "info": {"label": "SUDS Type 1"}}, {"id": "SUDS Measure Description 1", "type": "text", "info": {"label": "SUDS Measure Description 1"}}, {"id": "SUDS Type 2", "type": "text", "info": {"label": "SUDS Type 2"}}, {"id": "SUDS Measure Description 2", "type": "text", "info": {"label": "SUDS Measure Description 2"}}, {"id": "Additional SUDS", "type": "text", "info": {"label": "Additional SUDS"}}, {"id": "Additional SUDS Description", "type": "text", "info": {"label": "Additional SUDS Description"}}, {"id": "Comments", "type": "text", "info": {"label": "Comments"}}, {"id": "Comments - Additional Files", "type": "text", "info": {"label": "Comments - Additional Files"}}], "_links": {"start": "/api/3/action/datastore_search?resource_id=64563279-a530-44d6-870c-4102aa2f0852", "next": "/api/3/action/datastore_search?resource_id=64563279-a530-44d6-870c-4102aa2f0852&offset=100"}, "total": 73, "total_was_estimated": false}}